Skip to main content
Schneider Electric LV848354

Schneider Electric LV848354 MasterPact MTZ2 Drawout Circuit

MPN LV848354
Active

Schneider Electric MasterPacT MTZ2, LV848354, drawout circuit breaker, 4P, 4000 A at 40 °C, H2 100 kA 415 V AC performance type.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV848354 specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch150 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Mechanical life cycles20000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The Schneider Electric LV848354 is a MasterPact MTZ2 drawout circuit breaker, 4-pole, rated 4000 A at 40 °C. This is a Category B breaker, meaning it provides selectivity with upstream devices during a fault, so only the downstream section clears. The drawout mounting means the breaker slides into a chassis on rails or a base plate, making it serviceable without disconnecting main power cables — a real advantage when you're swapping a unit in a live panel. The chassis adds 403 mm depth and 556 mm width; without it, the breaker alone is 300 mm deep and 493 mm wide. Connection pitch is 150 mm, and both front and rear connections are available.

Electrical performance and ratings

The LV848354 is rated for 690 V AC operational voltage with an insulation voltage of 1000 V AC. Its service breaking capacity (Ics) is 100 kA at 220/415 V and 440 V, 85 kA at 500/525 V and 660/690 V. Making capacity (Icm) reaches 220 kA at 415/440 V. Short-time withstand (Icw) is 85 kA for 0.5 s and 1 s, 75 kA for 3 s — important for coordinating with downstream breakers in a selective system. Electrical durability is rated at 6000 cycles under AC-3 duty at 440/690 V, and 5000 cycles at 440 V under EN/IEC 60947-2. Maximum breaking time is 25 ms; closing response time is 70 ms. Power dissipation is 900 W — factor that into panel cooling.

Standards and environmental limits

The breaker complies with EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-2 Annex H, and IEC 61557-12. IP30 protection — fine for enclosed switchgear, not for washdown areas.

Sensor ratings and control

The breaker supports sensor ratings of 2000 A, 2500 A, 3200 A, and 4000 A — the 4000 A rating matches the breaker's own In. It ships without a control unit; control is via push-button. Neutral position is right. Impulse withstand voltage is 12 kV.

MPN
LV848354