Skip to main content
Schneider Electric LV848760

LV848760 MasterPact MTZ2 25 HA10 Switch Disconnector, 2500 A

MPN LV848760
Active

Schneider Electric MasterPact MTZ2 25 HA10 switch disconnector, LV848760, 2500 A, 1150 V AC, 105 kA Icm, 4P drawout.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV848760 key specifications
ParameterValue
Control typePush-button
Main product or component typeSwitch disconnector
Voltage1150 V AC 50/60 Hz conforming to EN/IEC 60947-3
Insulation voltage ui1250 V AC 50/60 Hz conforming to EN/IEC 60947-3
Current2500 A AC 50/60 Hz 1150 V
Utilization categoryAC-23 A AC-3
IP ratingIP30
Terminal pitch115 mm
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV848760 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-4-1
Depth403 mm
Width556 mm
Height439 mm
Electrical life cyclesAC-23 A: 500 cycles 1150 V AC 50/60 Hz conforming to EN/IEC 60947-3
ApplicationDistribution
Safety categoryHA10
Operating temperature-25...70 °C

Product details

The Schneider Electric LV848760 is a MasterPact MTZ2 25 HA10 switch disconnector rated for 2500 A at 1150 V AC, 50/60 Hz, with a short-circuit making capacity of 105 kA peak at that voltage. It's a 4-pole drawout unit built to EN/IEC 60947-3, suitable for isolation with a visible break indicator and contact position indicator. The drawout chassis mounting lets you rack the unit in and out for maintenance without disturbing the bus — a standard feature for high-current distribution switchgear.

The 2500 A rated operational current (Ie) at 1150 V AC tells you this unit handles full-load current for large distribution feeders or heavy motor loads in AC-23A and AC-3 duty. AC-23A covers occasional switching of motor loads with inrush; AC-3 covers routine motor starting. The 105 kA peak making capacity (Icm) means it can close onto a fault without welding contacts — critical for coordination in high-fault-current installations. Short-time withstand (Icw) is 50 kA for 1 s or 3 s, giving downstream breakers time to clear before the disconnect takes stress. Rated insulation voltage (Ui) is 1250 V AC, and impulse withstand (Uimp) is 12 kV — these confirm the part is designed for 1150 V systems with margin.

Drawout mounting on a chassis means the unit slides into a fixed cradle with 115 mm connection pitch. Panel cutout must accommodate the 556 mm width, 439 mm height, and 403 mm depth. Push-button control is integral; no separate actuator needed.

MPN
LV848760