Skip to main content
Schneider Electric LX1FK090

TeSys LX1FK090 Contactor Coil, 90 V AC 50/60 Hz

MPN LX1FK090
Active

Schneider Electric TeSys LX1FK090, contactor coil, 90 V AC 50/60 Hz, without built-in suppressor module.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LX1FK090 specifications
ParameterValue
Control circuit typeAC 50/60 Hz
Main product or component typeContactor coil
Coil voltage90 V AC 50/60 Hz
Temp operating max55 °C
Temp operating min-5 °C
Mechanical life cycles10 Mcycles
Operating time100...170 ms opening 40...75 ms closing
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX1FK090 is a replacement contactor coil from the Schneider Electric TeSys range, designed for 90 V AC control circuits at 50/60 Hz. It is a field-replaceable component for TeSys D, K, and F contactors — the coil alone, not the full contactor assembly. On the BOM, this is the part you order when the coil fails or you need a different control voltage for an existing contactor base.

The 90 V AC coil pulls in at 0.85 to 1.1 times Uc (76.5 to 99 V) and drops out between 0.3 and 0.5 Uc (27 to 45 V). That drop-out margin matters: if your control transformer sags under load, the coil stays sealed until the voltage falls below 27 V, preventing chatter on marginal supply. Opening time runs 100 to 170 ms, closing 40 to 75 ms — fast enough for most motor-starting sequences but not for high-speed jogging circuits. That rate translates to one operation every 1.5 seconds — adequate for conveyor indexing or pump cycling, but not for high-frequency solenoid valves. The coil draws 6 ohms inrush and 134 ohms holding at 20 °C, so the holding current is roughly 0.67 A at 90 V — factor that into your control transformer sizing. This coil ships without a built-in suppressor module. For inductive-load switching on the same control circuit, you will need an external RC snubber or varistor across the coil terminals to protect PLC outputs or relay contacts from the back-EMF spike on dropout.

Deployment context

The coil mounts onto the contactor base in the panel — no DIN-rail space consumed beyond the contactor itself. The 90 V AC control circuit is common in North American 480 V motor control centers where a 480/120 V control transformer feeds the coil; verify your control transformer secondary matches 90 V before specifying.

MPN