Skip to main content
Schneider Electric LX4FF040

TeSys LX4FF040 Contactor Coil, 48 V DC, Obsolete

MPN LX4FF040
Obsolete

TeSys F, contactor coil, LX4FF040, 48 V DC wide range, 30...40 ms closing, 30...50 ms opening, without built-in suppressor module.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LX4FF040 specifications
ParameterValue
Control circuit typeDC wide range
Main product or component typeContactor coil
Coil voltage48 V DC
Temp operating max70 °C
Temp operating min-55 °C
Mechanical life cycles1 Mcycles
Operating time30...40 ms closing 30...50 ms opening
Operating temperature-67...158 °F (-55...70 °C)

Product details

The LX4FF040 is a replacement contactor coil from the TeSys F range, designed for 48 V DC wide-range control circuits. It is the service-part coil that mates with TeSys F contactor frames — not a standalone contactor, but the interchangeable coil assembly you swap when the original coil fails or you need to change the control voltage on an existing contactor. Key operating parameters: closing time 30...40 ms, opening time 30...50 ms. Coil inrush power is 560 W at 68 °F (20 °C), dropping to 4.5 W holding power at the same temperature. The average resistance measures 2.86 Ohm inrush and 391 Ohm holding at 68 °F (20 °C). The coil carries an inductance of 27 H when closed. Control voltage limits at 158 °F (70 °C): operational range 0.7...1.25 Uc, drop-out range 0.2...0.45 Uc. The coil has no built-in suppressor module. If your application drives the coil from a PLC output or solid-state relay, you will need an external flyback diode or RC snubber across the coil terminals to protect the switching device from the inductive kickback. The 27 H inductance stores significant energy when energized.

What replaces it — the cross-reference question

The manufacturer does not list a direct drop-in successor order code for the LX4FF040 in the lifecycle record. Within the TeSys F family, the current-production coil range uses a different part-numbering scheme and may have different mounting or electrical characteristics. A pin-for-pin equivalent is not guaranteed without checking the specific contactor frame and coil mounting interface.

MPN
LX4FF040