Skip to main content
Schneider Electric LX4FH090

TeSys LX4FH090 Contactor Coil, 110 V DC, Obsolete

MPN LX4FH090
Obsolete

TeSys F, contactor coil, LX4FH090, 110 V DC wide range, 40-50 ms closing, 40-65 ms opening, 1 Mcycles mechanical durability.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LX4FH090 specifications
ParameterValue
Control circuit typeDC wide range
Main product or component typeContactor coil
Coil voltage110 V DC
Temp operating max70 °C
Temp operating min-55 °C
Mechanical life cycles1 Mcycles
Operating time40...50 ms closing 40...65 ms opening
Operating temperature-67...158 °F (-55...70 °C)

Product details

The LX4FH090 is a replacement contactor coil for the TeSys F series, rated for 110 V DC wide-range control circuits. It is the component that energizes the contactor armature — without it, the main power poles do not close. The closing time of 40 to 50 ms and opening time of 40 to 65 ms define the mechanical response window for the contactor it drives. The coil draws 750 W inrush at 20 °C, then holds at 5 W once the armature seats. The inrush resistance is 11 Ω, rising to 2120 Ω in the holding state. The inductance of the closed circuit is 287 H, which governs the L/R time constant for suppression circuit selection — critical when adding a free-wheeling diode or varistor across the coil terminals. The ambient temperature range spans -55 °C to +70 °C, covering most industrial enclosure environments. The coil has no built-in suppressor module, so external transient suppression must be added by the panel builder.

Because this is a service part for an installed base of TeSys F contactors, the procurement decision hinges on whether the contactor frame itself is still in service. If the contactor is also being replaced, a complete contactor assembly with an integrated coil may be a more reliable path than sourcing an obsolete coil through secondary markets.

Control voltage and operating limits

The control circuit voltage is 110 V DC, with a wide-range operational band of 0.7 to 1.25 times Uc (77 V to 137.5 V DC at 70 °C). Drop-out occurs between 0.2 and 0.45 Uc (22 V to 49.5 V DC). This wide dropout margin means the coil releases reliably even with significant voltage sag on the DC bus — useful in installations with long control wiring or shared DC supplies.

MPN
LX4FH090