Skip to main content
Schneider Electric LX9FF550

TeSys LX9FF550 Specific Contactor Coil, 550 V AC, Obsolete

MPN LX9FF550
Obsolete

Schneider Electric TeSys F, LX9FF550, specific contactor coil, 550 V AC 40-400 Hz low consumption, 130 ms opening / 35 ms closing, 10 Mcycles mechanical durability.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LX9FF550 specifications
ParameterValue
Control circuit typeAC 40...400 Hz low consumption
Main product or component typeSpecific contactor coil
Coil voltage550 V AC 40...400 Hz
Temp operating max55 °C
Temp operating min-5 °C
Mechanical life cycles10 Mcycles
Operating time130 ms opening 35 ms closing
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX9FF550 is a specific replacement coil for TeSys F contactors, rated for 550 V AC control circuits at 40-400 Hz. It's a low-consumption design — inrush power sits at 690-855 VA, dropping to 6.6-8.1 VA holding — which means the control transformer and wiring only need to handle the brief surge, not a continuous high draw. The coil draws 331.4 Ω inrush and 12447 Ω holding at 68 °F (20 °C).

Opening time is 130 ms and closing time is 35 ms — the asymmetry matters in sequencing: the contactor opens slower than it closes, so if you're interlocking with another device, the break-before-make window is driven by the opening delay. The coil has no built-in suppressor module, so you'll need to add an external RC snubber or varistor across the coil terminals to protect the control circuit from the inductive kick during dropout. Control voltage limits are 0.85-1.1 Uc for operation and 0.35-0.55 Uc for dropout at 131 °F (55 °C). That dropout range is wide — the coil releases at roughly 193-303 V on a 550 V nominal supply — so it won't drop out on a moderate sag, but a hard brownout below 193 V will release the contactor. Heat dissipation is 5.9-7.2 W, which adds to the panel thermal load; in a sealed enclosure, factor that into the cooling budget. That's about 40 cycles per minute continuous — fine for most motor starting and switching duty, but if you're cycling faster than that (e.g., in a rapid-indexing application), you'll exceed the mechanical rating.

Deployment Context

This coil mounts directly onto the TeSys F contactor frame — it's a specific replacement, not a universal fit. Because it's a low-consumption coil, it pairs well with PLC-sourced control signals through an interposing relay, keeping the PLC output contact loading low.

MPN
LX9FF550