Skip to main content
Schneider Electric MGN60623

MGN60623 C60H MCB, 3A C-curve 2P, 30 kA breaking capacity

MPN MGN60623
Obsolete

Schneider Electric C60H Multi9 miniature circuit-breaker, MGN60623, 3 A rated current, C-curve, 2-pole, 30 kA Icu at 240 V AC, thermal-magnetic trip, 35 mm DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN60623 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase 415 V AC 50/60 Hz phase to phase
Breaking capacity30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 25 kA Icu at 125 V DC phase to phase conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C

All specifications

MGN60623 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles10000 cycles conforming to EN/IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The MGN60623 is a Schneider Electric C60H miniature circuit-breaker from the Multi9 range, rated 3 A at 50 °C with a C-curve trip characteristic. The C-curve means the magnetic trip fires at 5 to 10 times rated current — here, 8.5 x In ±20 % — so it handles moderate inrush from motor starters or small transformers without nuisance tripping, yet clears a hard short fast. The 2-pole configuration protects both lines in a single-phase DC or split-phase AC circuit; the part is also isolation-rated per EN/IEC 60947-2, so it doubles as a service disconnect. Breaking capacity hits 30 kA Icu at 240 V AC phase-to-phase, dropping to 15 kA at 415 V AC and 10 kA at 440 V AC. That 30 kA figure is high for a 3 A frame; it gives headroom in high-fault panels without stepping up to a larger case size.

The 73 mm depth and 81 mm height fit standard distribution boards and sub-panels. The toggle gives local ON/OFF indication and a contact position indicator confirms the state of the moving contacts. Earth-leakage protection is handled by a separate block, so you can add an RCD module downstream without swapping the breaker.

MPN