Schneider Electric MGN60862

MGN60862 C60N MCB, 1A C-curve, 10 kA, 1P, Multi9

MPN MGN60862
Obsolete

Schneider Electric Multi9 C60N, MGN60862, miniature circuit breaker, 1 A, C-curve, 1 pole, 10 kA Icu at 240 V AC, EN/IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN60862 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage240 V AC 50/60 Hz phase to neutral
Breaking capacity10 kA Icu at 240 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2 3 kA Icu at 415 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C

All specifications

MGN60862 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
Depth73 mm
Width18 mm
Height81 mm
Electrical life cycles10000 cycles conforming to EN/IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The MGN60862 is a 1-pole C60N miniature circuit breaker from the Multi9 range, rated 1 A with a C-curve trip characteristic. It is designed for distribution applications and complies with EN/IEC 60947-2, which covers the performance and safety requirements for low-voltage circuit breakers used in industrial and commercial installations.

The 1 A rated current (In) at 50 °C means this breaker protects a circuit drawing up to 1 A continuously without nuisance tripping. The C-curve (magnetic tripping limit of 8.5 x In +/- 20 %) means it will hold through moderate inrush currents — typical for small transformers, lighting ballasts, or control power supplies — and trip fast on a hard short. The service breaking capacity (Ics) is 75 % of those values: 7.5 kA at 240 V and 2.25 kA at 415 V. That means after clearing a fault at the Ics level, the breaker is still usable — it doesn't have to be replaced after every trip. Rated operational voltage is 240 V AC phase-to-neutral.

Width is 18 mm (2 x 9 mm pitches), so it occupies one standard modular position in a distribution board. Tightening torque for the power circuit is 2 N·m. Pollution degree 3 per EN/IEC 60947-2 means it's rated for conductive pollution in industrial environments (e.g., occasional condensation).

MPN
MGN60862