Schneider Electric MGN61518

MGN61518 Multi9 C60H-DC 1P 50A C-Curve DC MCB, 10kA at 220 V

MPN MGN61518
Obsolete

Schneider Electric Multi9 C60H-DC, 1P, 50 A, C-curve, DC miniature circuit breaker, UL 489, 10 kA Icu at 220 VDC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN61518 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage12...250 V DC
Insulation voltage ui500 V DC EN/IEC 60947-2
Utilization categoryCategory A EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...185 °F (-40...85 °C)
Pollution degree3 EN/IEC 60947-2

All specifications

MGN61518 additional specifications
ParameterValue
ColorGray
Depth2.9 in (73 mm)
Width0.7 in (18 mm)
Height3.2 in (81 mm)
Electrical life cycles3000 cycles L/R = 2 ms
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-13...158 °F (-25...70 °C)

Product details

The MGN61518 is a Schneider Electric Multi9 C60H-DC single-pole DC miniature circuit breaker rated 50 A at 25 °C, with a C-curve trip characteristic (magnetic tripping at 8.5 x In ±20%). It breaks up to 10 kA Icu at 220 V DC per IEC 60947-2 and GB 14048.2, with symmetrical ratings of 20 kA at 110 V DC and 6 kA at 250 V DC. The thermal-magnetic trip unit handles DC network protection in distribution panels where overcurrent and short-circuit isolation are needed on a single pole.

DC breaking capacity — what the ratings mean

At 110 V DC the interrupting rating doubles to 20 kA, which covers most low-voltage DC bus faults in telecom or battery-backed distribution. The 6 kA at 250 V DC is the ceiling for higher-voltage strings. All three ratings are symmetrical per IEC 60947-2 — the breaker is certified to the same standard as AC industrial breakers, but optimized for DC arc extinction. The limitation class of 3 means it lets through a limited amount of let-through energy, which aids downstream component coordination.

Clip-on DIN-rail mount, 2 modules of 9 mm pitch (18 mm wide). The 73 mm depth leaves clearance in standard 80 mm deep enclosures. Strip length is 14 mm.

MPN