Schneider Electric MGN61803

MGN61803 Multi9 C60H-DC MCB, 1P, 13 A, Curve B, DC

MPN MGN61803
Obsolete

Schneider Electric Multi9 C60H-DC, 1-pole miniature circuit breaker, 13 A rated current, curve B, 20 kA breaking capacity at 110 V DC, EN/IEC 60947-2, grey, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN61803 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage250 V DC 110 V DC 220 V DC
Insulation voltage ui500 V DC conforming to EN/IEC 60947-2
Breaking capacity20 kA Icu at 110 V DC conforming to EN/IEC 60947-2 10 kA Icu at 220 V DC conforming to EN/IEC 60947-2 6 kA Icu at 250 V DC conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C

All specifications

MGN61803 additional specifications
ParameterValue
Pollution degree3 conforming to EN 60947-2
ColorGrey
Depth73 mm
Width18 mm
Height81 mm
Electrical life cycles3000 cycles L/R = 2 ms
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

DC-rated MCB for distribution panels

The MGN61803 is a 1-pole Multi9 C60H-DC miniature circuit breaker from Schneider Electric, rated 13 A at 50 °C per EN/IEC 60947-2. It is designed for DC networks — the curve B magnetic trip triggers at 5.5 x In ±20 % DC, so it catches short-circuit faults fast while tolerating inrush from resistive or lightly inductive DC loads. The 20 kA Icu at 110 V DC means it can safely interrupt a fault up to that level without upstream cascading; at 220 V DC the breaking capacity is 10 kA, and at 250 V DC it is 6 kA.

Clip-on mounting to a standard DIN rail, 18 mm wide (2 x 9 mm pitches), 81 mm tall, 73 mm deep. Strip length is 14 mm; tighten to 2.5 N·m. The IP20 finger-safe front and IP40 modular enclosure suit enclosed panel mounting. Padlockable toggle with ON/OFF indication and a contact position indicator for isolation verification — the breaker is marked isolation-suitable per EN/IEC 60947-2.

MPN
MGN61803