Skip to main content
Schneider Electric MGN61806

MGN61806 Multi9 C60H-DC MCB, 1P, 25 A, Curve B, 20 kA DC

MPN MGN61806
Obsolete

Schneider Electric Multi9 C60H-DC, miniature circuit breaker, 1P, 25 A rated, curve B, 20 kA Icu at 110 V DC, clip-on DIN rail, grey.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN61806 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage250 V DC 110 V DC 220 V DC
Insulation voltage ui500 V DC conforming to EN/IEC 60947-2
Breaking capacity20 kA Icu at 110 V DC conforming to EN/IEC 60947-2 10 kA Icu at 220 V DC conforming to EN/IEC 60947-2 6 kA Icu at 250 V DC conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C

All specifications

MGN61806 additional specifications
ParameterValue
Pollution degree3 conforming to EN 60947-2
ColorGrey
Depth73 mm
Width18 mm
Height81 mm
Electrical life cycles3000 cycles L/R = 2 ms
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The MGN61806 is a Schneider Electric Multi9 C60H-DC miniature circuit breaker — a single-pole, thermal-magnetic breaker rated 25 A at 50 °C, curve B, built for DC networks. The key spec for a buyer: at 110 V DC it breaks 20 kA Icu per EN/IEC 60947-2, at 220 V DC it breaks 10 kA, and at 250 V DC it still holds 6 kA. The curve-B magnetic trip fires at 5.5 x In ±20 % DC — so for a 25 A breaker, the instantaneous trip point lands between 110 A and 165 A DC. That's a tight window compared to a C curve, which means it clears low-impedance faults faster. Use it on resistive or lightly inductive DC loads where you want nuisance-tripping kept low but still need fast short-circuit clearance.

Where this breaker fits in a panel

Clip-on DIN-rail mount, 18 mm per pole. Strip length is 14 mm; torque to 2.5 N·m. IP20 on the terminals, IP40 inside the modular enclosure. It's padlockable and has a clear ON/OFF indicator plus a contact-position flag, so a technician can verify isolation visually before reaching in. Pollution degree 3 and tropicalisation (2, per IEC 60068-2) mean it handles dusty, humid environments up to 95 % RH at 55 °C without derating.

MPN
MGN61806