Skip to main content
Schneider Electric MGN61844

MGN61844 Multi9 C60H-DC MCB, 4 A, 2P, DC Breaking 20 kA

MPN MGN61844
Obsolete

Schneider Electric Multi9 C60H-DC, miniature circuit breaker, 4 A, 2 poles, DC rated, breaking capacity 20 kA at 220 V DC, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN61844 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage250 V DC 500 V DC 220 V DC 440 V DC
Insulation voltage ui500 V DC conforming to EN/IEC 60947-2
Breaking capacity20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C

All specifications

MGN61844 additional specifications
ParameterValue
Pollution degree3 conforming to EN 60947-2
ColorGrey
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles3000 cycles L/R = 2 ms
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The MGN61844 is a Schneider Electric Multi9 C60H-DC miniature circuit breaker — a 2-pole, 4 A thermal-magnetic unit built for DC distribution circuits. The C-curve trips at 8.5 x In (34 A magnetic), which suits cable protection and moderate inrush loads like DC contactor coils.

The breaking capacity drops as voltage climbs: 20 kA at 220 V DC, 20 kA at 250 V DC, 10 kA at 440 V DC, and 6 kA at 500 V DC. That 6 kA at 500 V is the number to check if you're protecting a 500 V DC bus — it's lower than the headline 20 kA.

Panel integration

Clip-on DIN rail mount, 36 mm wide (4 x 9 mm pitches). Tunnel terminals accept up to 25 mm² rigid stranded or 16 mm² flexible; strip length 14 mm, torque to 2.5 N·m. IP20 finger-safe on the front, IP40 inside a modular enclosure. Padlockable toggle for lockout/tagout. The 73 mm depth leaves clearance behind a standard 80 mm deep enclosure.

MPN
MGN61844