MGN61848 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage250 V DC 500 V DC 220 V DC 440 V DC
Insulation voltage ui500 V DC conforming to EN/IEC 60947-2
Breaking capacity20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C

All specifications

MGN61848 additional specifications
ParameterValue
Pollution degree3 conforming to EN 60947-2
ColorGrey
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles3000 cycles L/R = 2 ms
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric MGN61848 is a Multi9 C60H-DC miniature circuit breaker — a 2-pole, 10 A rated, C-curve unit built specifically for DC circuits.

This breaker's interrupting capacity changes with system voltage, and that's the first thing to check when you're laying out a DC distribution board. At 220 V DC it's rated 20 kA Icu; at 250 V DC it holds at 20 kA. Step up to 440 V DC and it drops to 10 kA; at 500 V DC it's 6 kA. The rated insulation voltage (Ui) is 500 V DC, and the rated operational voltages (Ue) cover 220 V DC, 250 V DC, 440 V DC, and 500 V DC. That 500 V DC Ui means the internal clearances are sized for that ceiling, but the interrupting rating at 500 V is only 6 kA — the breaker can sit on a 500 V rail, but it can't interrupt a high-energy fault there.

Thermal-magnetic trip and C-curve behaviour

It's a thermal-magnetic trip with a C-curve. The magnetic trip threshold is 8.5 x In ±20% DC — so for this 10 A unit, the magnetic pickup sits between roughly 68 A and 102 A DC. That's a fairly tight window compared to some DC-rated breakers, which matters if you're protecting a load with a moderate inrush. The thermal element handles sustained overloads; the magnetic element clears short-circuits fast.

Mounting and wiring details for the panel builder

Clip-on mounting on a standard DIN rail. It occupies 4 x 9 mm pitches — so 36 mm wide — which is a standard 2-module width for a 2-pole breaker. It can take up to three 1 mm² conductors in one terminal if you're daisy-chaining.