Schneider Electric MGN61881 Multi9 C60H-DC MCB, 8 A, 2P, K-C

MPN MGN61881
Obsolete

Schneider Electric Multi9 C60H-DC, MGN61881, miniature circuit breaker, 2-pole, 8 A, K-curve, 20 kA breaking capacity at 250 V DC, DIN-rail clip-on.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN61881 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage250 V DC 500 V DC 220 V DC 440 V DC
Insulation voltage ui500 V DC conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN 60947-2

All specifications

MGN61881 additional specifications
ParameterValue
ColorGrey
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles3000 cycles L/R = 2 ms
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

DC circuit protection with K-curve selectivity

The Schneider Electric MGN61881 is a Multi9 C60H-DC miniature circuit breaker rated 8 A at 50 °C per EN/IEC 60947-2, with a K-curve magnetic trip set at 12 x In ±20 % for DC networks. The 2-pole configuration breaks both legs simultaneously, essential for DC fault clearing where no natural zero-crossing exists. Breaking capacity reaches 20 kA Icu at 250 V DC and 10 kA at 440 V DC, so it handles high-energy battery banks or DC bus faults without cascading upstream. The thermal-magnetic trip unit combines a bimetal for overload protection and a solenoid for short-circuit response. The K-curve characteristic means the magnetic threshold is higher than a standard B or C curve — typically 8 to 12 times rated current — which avoids nuisance tripping on inrush from DC motor drives or capacitive loads while still clearing hard faults. This makes the C60H-DC a fit for DC distribution panels, photovoltaic combiners, and battery-string protection where load inrush is a known factor.

The MGN61881 clips onto standard 35 mm DIN rail (EN 60715) and occupies 4 x 9 mm pitches — 36 mm wide — with a depth of 73 mm and height of 81 mm. Tunnel-type terminals accept up to 25 mm² rigid stranded or 16 mm² flexible, with a strip length of 14 mm and tightening torque of 2.5 N·m. The IP20 finger-safe front and IP40 modular enclosure rating suit enclosed panel mounting; the grey housing includes a padlockable toggle and ON/OFF visual indication. Rated insulation voltage (Ui) is 500 V DC, and operational voltage (Ue) covers 220 V, 250 V, 440 V, and 500 V DC networks.