Skip to main content
Schneider Electric MGP0802L31

Schneider Electric MGP0802L31 PowerPacT 4 MCCB, 80A, 25kA

MPN MGP0802L31
Obsolete

Schneider Electric PowerPacT 4, molded case circuit breaker, 2P, 80A, 415V AC, 25kA Icu/Ics, thermal-magnetic TM-D trip unit.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGP0802L31 specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage415 V AC 50/60 Hz
Insulation voltage ui750 V
Phase connectionL3 - L1
Electrical life cycles20000 cycles at 277 V In/2 10000 cycles at 277 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Thermal protection adjustment range80 A

Product details

The Schneider Electric MGP0802L31 is a PowerPacT 4 molded case circuit breaker (MCCB) with a 2-pole configuration, rated 80 A at 40 °C and 415 V AC 50/60 Hz. It is certified to BS EN 60947-2, the standard for low-voltage switchgear and controlgear circuit breakers, and carries suitability for isolation per that standard — meaning it provides visible isolation when open, a requirement for safe maintenance lockout.

In a warmer panel, derate per the manufacturer's thermal curve; the TM-D trip unit is fixed at 80 A, not adjustable. It means the breaker's full interrupting capacity is available for both rare worst-case faults (Icu) and more frequent service-level faults (Ics), simplifying selective coordination studies. Rated insulation voltage (Ui) of 750 V and impulse withstand (Uimp) of 8 kV give headroom for 480 V systems and transient immunity in industrial environments with motor starts or nearby lightning. Mechanical durability of 20,000 cycles and electrical durability of 20,000 cycles at rated current (derating to 10,000 cycles at 2× In) — this is a distribution breaker, not a switching device; expect it to cycle rarely in normal service.

Panel-mounted on a backplate, with horizontal or vertical orientation allowed. Occupies 2 module spaces of 35 mm width each — standard for DIN-rail-mount enclosures, though the breaker itself is screw-mounted to the backplate, not snap-on DIN rail. Phase connection is L3-, meaning line and load connect to the outer poles of the 2-pole device. Toggle control type for manual on/off and trip reset.

MPN