Skip to main content
Schneider Electric MGP1603NAX

MGP1603NAX PowerPact Switch Disconnector, 160A, 3P

MPN MGP1603NAX
Obsolete

Schneider Electric PowerPact 4, switch disconnector, 3P, 160 A, toggle control, backplate mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGP1603NAX key specifications
ParameterValue
Control typeToggle
Main product or component typeSwitch disconnector
Voltage415 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
Utilization categoryAC-22 A AC-23 A DC-22 A DC-23 A
IP ratingIP40
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degree3 conforming to EN/IEC 60664-1

All specifications

MGP1603NAX additional specifications
ParameterValue
Depth86 mm
Width105 mm
Height161 mm
Electrical life cycles30000 cycles 440 V In/2 15000 cycles 440 V In
Mechanical life cycles40000 cycles
ApplicationIsolation
Operating temperature-25...70 °C

Product details

The MGP1603NAX is a 3-pole switch disconnector from the PowerPact 4 range, rated 160 A continuous. It's built for isolation duty in panelboards up to 250 A or 400/630 A, with a toggle operator and backplate mounting. The utilisation categories cover AC-22A, AC-23A, DC-22A, and DC-23A — meaning it handles mixed resistive-inductive loads as well as motor switching on both AC and DC circuits.

The 160 A rated current (In) is the continuous carry rating — the switch can pass that current indefinitely without overheating. The short-time withstand current (Icw) is 2500 A for 1 s or 3 s, and 960 A for 20 s, which tells you how much fault current the switch can survive while closed before the upstream protection clears it. That's a coordination number for the panel designer: the upstream breaker or fuse must open within those time-current limits. That puts it in the standard 400 V-class panel range. The pollution degree 3 rating (EN/IEC 60664-1) means it's designed for environments where conductive pollution can occur — typical for industrial control panels not in a clean room. Mechanical durability is 40,000 cycles; electrical durability varies by load — 30,000 cycles at 440 V at rated current, dropping to 15,000 cycles at twice rated current (In/2). That's a practical limit for maintenance planning: if this switch sees frequent operation under heavy load, plan for contact inspection well before those cycle counts.

IK07 impact rating covers the usual bumps during installation. The toggle handle gives a visible contact position indicator, which is a requirement for isolation switches per BS EN 60947-3 — you can see at a glance whether the circuit is open or closed.