Skip to main content
Schneider Electric RM4UA31Q

Schneider Electric RM4UA31Q Voltage Measurement Relay, 2 C/O

MPN RM4UA31Q
Active

Schneider Electric Zelio Control RM4UA31Q voltage measurement relay, 2 C/O contacts, adjustable hysteresis 5-30%, adjustable time delay 0.05-30 s, 22.5 mm wide, IP20 terminals.

$235.94 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

RM4UA31Q specifications
ParameterValue
TypeVoltage measurement relay
Current2 A 158 °F (70 °C) 24 V DC-13 IEC 60947-5-1/1991 2 A 158 °F (70 °C) 24 V DC-13 VDE 0660 3 A 158 °F (70 °C) 115 V AC-15 IEC 60947-5-1/1991 3 A 158 °F (70 °C) 115 V AC-15 VDE 0660 3 A 158 °F (70 °C) 24 V AC-15 IEC 60947-5-1/1991 3 A 158 °F (70 °C) 24 V AC-15 VDE 0660 3 A 158 °F (70 °C) 250 V AC-15 IEC 60947-5-1/1991 3 A 158 °F (70 °C) 250 V AC-15 VDE 0660 0.1 A 158 °F (70 °C) 250 V DC-13 IEC 60947-5-1/1991 0.1 A 158 °F (70 °C) 250 V DC-13 VDE 0660 0.3 A 158 °F (70 °C) 115 V DC-13 IEC 60947-5-1/1991 0.3 A 158 °F (70 °C) 115 V DC-13 VDE 0660
IP ratingIP20 / IP50
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max65 °C
Temp operating min-20 °C
Storage temperature-40...185 °F (-40...85 °C)
Pollution degree3 IEC 60664-1
Depth3.1 in (80 mm)
Width0.9 in (22.5 mm)
Height3.07 in (78 mm)
Mechanical life cycles30000000 cycles
Operating temperature-4...149 °F (-20...65 °C)

Product details

Voltage monitoring relay with adjustable trip thresholds

The RM4UA31Q is a voltage measurement relay from the Zelio Control range, designed for overvoltage or undervoltage detection in industrial control circuits. It monitors a single-phase AC supply and trips its output relays when the measured voltage crosses the set threshold. Two key adjustments let you tune the response: hysteresis is settable from 5 to 30 % of the threshold voltage, and the output time delay is adjustable from 0.05 to 30 s. This means you can prevent nuisance tripping on transient dips or surges while still catching sustained faults.

Contact ratings and switching capacity

The relay provides two changeover (2 C/O) output contacts with silver-nickel (90/10) material, rated for 3 A at 250 V AC-15 per IEC 60947-5-1 — the standard for switching electromagnetic loads like contactor coils and solenoid valves. At 24 V DC-13 (switching DC solenoids), the rating is 2 A. Minimum switching capacity is 10 mA at 12 V, which covers PLC digital inputs and low-power signal circuits. The maximum switching voltage is 440 V AC, so the contacts can handle line-voltage control circuits in most panel environments.

Compliance and environmental ratings

Designed to EN/IEC 60255-6 (measuring relays and protection equipment), the RM4UA31Q carries a dielectric test voltage of 2.5 kV and withstands a 4.8 kV non-dissipating shock wave. Pollution degree 3 per IEC 60664-1 means it is rated for industrial environments with conductive pollution. EMC compliance covers electrostatic discharge (6 kV contact / 8 kV air, level 3 per IEC 61000-4-2) and fast transients at 2 kV (level 3 per IEC 61000-4-4). The enclosure is IP50; the terminals are IP20 — suitable for installation inside a clean, dry panel.

MPN
RM4UA31Q