Skip to main content
Schneider Electric TA10D4L0504TPE

Schneider Electric TA10D4L0504TPE TransferPacT ATS, 50 A, 4P

MPN TA10D4L0504TPE
Active

Schneider Electric TransferPacT TA10D4L0504TPE, automatic transfer switch, 50 A, 4P, PC class, 400 V AC, IEC 60947-6-1.

$764.41 – $1,416.37 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

TA10D4L0504TPE key specifications
ParameterValue
Control type4 push-buttons
Display typeLCD screen
Main product or component typeAutomatic transfer switch
Voltage400 V AC 50/60 Hz
Insulation voltage uiSwitch: 800 V Controller: 500 V
Current50 A
Utilization categoryAC-33B
Terminal pitch18 mm
Connection surface topScrewed
Connection surface bottomScrewed
Temp storage max85 °C
Temp storage min-40 °C

All specifications

TA10D4L0504TPE additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3
Depth94 mm
Width310 mm
Height147 mm
Mechanical life cycles8000 cycles
ApplicationChange source of supply
Operating temperature-25...70 °C

Product details

The Schneider Electric TA10D4L0504TPE is a TransferPacT automatic transfer switch rated 50 A at 400 V AC, 4 poles, PC class per IEC 60947-6-1. It's built for uninterrupted-duty changeover of the supply source — think backup generator or secondary utility feed kicking in when the primary drops. The AC-33B utilization category means it handles mixed loads including motors, resistive, and some lighting, not just straight resistive. Rated short-time withstand current (Icw) is 5 kA for 0.1 s, and the short-circuit making capacity (Icm) hits 15 kA for the switch alone, or 75 kA with an upstream protection breaker. That's the kind of fault-closing capability you want when the line is down and you're throwing the switch onto a bolted fault.

The front face is IP40 in auto mode (splash-resistant enough for a clean panel face), and IP20 inside the enclosure when you're in manual mode — so keep the enclosure door closed for washdown areas. Screwed terminals top and bottom, 4 poles. Dimensions: 310 mm wide, 147 mm tall, 94 mm deep. That's a decent footprint — plan your gland plate and DIN rail layout accordingly.

MPN