Schneider TM3DI8 Input Module, 8 x 24VDC, 84.6mm depth

MPN TM3DI8
Active

Schneider Electric Modicon TM3, 8-input discrete input module, 24 V DC, sink/source, 3.4 kOhm, panel or DIN-rail mount.

$78.74 – $225.00 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

TM3DI8 specifications
ParameterValue
Main product or component typeDiscrete input module
IP ratingIP20
Maximum cable distance between devicesUnshielded cable <98.4 ft (30 m) regular input
Temp storage max70 °C
Temp storage min-25 °C
Temp operating max35 °C
Temp operating min-10 °C
Storage temperature-13...158 °F (-25...70 °C)
Pollution degree2
Depth3.3 in (84.6 mm)
Width1.08 in (27.4 mm)
Height3.5 in (90 mm)
AWG gauge0.0003...0.004 in² (0.2...2.5 mm²) / AWG 24...AWG 14 with solid cable
ApplicationIndustrial Application
Input impedance3.4 kOhm
Discrete input logicSink or source (positive/negative)
Operating temperature14...95 °F (-10...35 °C) vertical installation) 14...131 °F (-10...55 °C) horizontal installation)

Product details

The module in practice

The TM3DI8 is an 8-channel discrete input module in the Modicon TM3 family, accepting 24 V DC signals from sensors, pushbuttons, or limit switches. Each channel can be wired as sink or source, which means it handles both NPN and PNP outputs without extra hardware. That’s a real advantage when you’re consolidating different sensor types onto one backplane. Input impedance is 3.4 kOhm, drawing 7 mA per channel at 24 V. That’s within the typical range for IEC 61131-2 Type 1 inputs, so it will reliably see a signal from most industrial sensors. The guaranteed ON threshold is 15 V at 2.5 mA; OFF is below 5 V and 1 mA. Response time is 4 ms maximum for both turn-on and turn-off. The module is powered through the TM3 bus backplane – no separate supply needed. Typical consumption is 22 mA at 5 V DC, 5 mA on the bus. Isolation between channels and bus is 500 V AC.

It clips onto standard TH35-15 or TH35-7.5 DIN rail, or you can bolt it to a panel with the optional fixing kit. Physical footprint: 84.6 mm deep, 27.4 mm wide, 90 mm high. Rated for IP20, pollution degree 2. Operates from -10 to +55 °C horizontally, or -10 to +35 °C if mounted vertically. Humidity tolerance: 10–95 % non-condensing. Vibration resistance on DIN rail is 3.5 mm at 5–8.4 Hz and 3 gn at 8.4–150 Hz. Shock: 15 gn for 11 ms. Wiring uses an 11-pin removable screw terminal block, pitch 5.08 mm, accepting 0.2–2.5 mm² (AWG 24–14 solid). Maximum unshielded cable run from sensor to module is 30 meters for standard inputs.