Skip to main content
Schneider Electric VW3A46161

Schneider VW3A46161 Passive Filter, 19A, 480V, 60Hz, Altivar

MPN VW3A46161
Active

Schneider Electric Altivar series VW3A46161 passive harmonic filter, 19 A rated, 480 V, 60 Hz, 3-phase, for 11 kW/15 hp drives.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

VW3A46161 specifications
ParameterValue
Main product or component typePassive filter
IP ratingIP20 / IP55
Temp storage max65 °C
Temp storage min-25 °C
Temp operating max60 °C
Temp operating min5 °C
Cos phi1 (150 % of line current) 0.85 (75 % of line current) 0.99 (100 % of line current)
Efficiency98%
Operating temperature45...60 °C (with current derating 3 % per °C) 5...45 °C (without current derating)

Product details

The VW3A46161 is a passive harmonic filter from the Altivar accessory family, sized for 11 kW / 15 hp drives across the ATV61, ATV71, ATV630, ATV650, ATV930, and ATV950 ranges. It sits between the line supply and the drive input, knocking down current harmonics to meet IEC 61000-3-4, IEC 61000-3-12, and G5/4 engineering recommendation limits. One filter per drive — no sharing across multiple units. Rated 19 A input / 19.5 A output at 480 V ±10 %, 60 Hz, three-phase. Efficiency hits 98 %, so the 258 W thermal loss figure tells you what to budget for panel ventilation. Class F insulation, IP20 as a standalone unit, IP55 when enclosure-mounted.

THDI and power factor — what the numbers mean

THDI depends on which drive generation you bolt it to. On the older ATV61H, ATV71H, ATV71P, and ATV71W frames at 11 kW / 15 hp, it holds THDI to 10 %. On the ATV61W and the newer ATV630 / ATV650 / ATV930 / ATV950 platform, it pulls that down to 5 %. That's the difference between a borderline installation and one that sails past most utility harmonic limits without an active front end. Power factor correction is load-dependent. At 150 % of line current the filter delivers cos φ of 1 (unity). At full rated current it sits at 0.99, and at 75 % load it drops to 0.85. The takeaway: keep the drive loaded above 75 % to stay in the clean PF band.

Terminals X1-1 through X2-3 accept 0.5 to 10 mm²; the A and B terminals take 2.5 mm². Strip length and torque aren't listed here, but the spring-cage style on the Altivar accessory line typically needs 8 mm strip and a small screwdriver. Mount it close to the drive line input — long cables between filter and drive kill the HF attenuation. Operating ambient from 5 °C to 45 °C with no derating. Above 45 °C up to 60 °C, derate 3 % per °C. Storage in original packaging from -25 °C to 55 °C; transport range extends to 65 °C. Humidity 5 to 85 % non-condensing. Altitude derating kicks in above 1000 m at 5 % per additional 1000 m up to 4000 m.