Skip to main content
Schneider Electric VW3A5217

Schneider VW3A5217 Sinus Filter, 45 A, 690 V AC, for Altivar

MPN VW3A5217
Active

Schneider Electric, Altivar Process sinus filter, VW3A5217, 45 A rated current, 690 V AC max, 2 kHz switching frequency, 70 Hz max output frequency, UL 508.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

VW3A5217 specifications
ParameterValue
Main product or component typeSinus filter
Frequency2 kHz
IP ratingIP00
Temp storage max65 °C
Temp storage min-40 °C
Temp operating max45 °C
Temp operating min-10 °C
Storage temperature-40...65 °C
Pollution degree2 conforming to EN 50178
Operating temperature-10...45 °C

Product details

The VW3A5217 is a sinus filter for Altivar Process variable speed drives, rated 45 A continuous with a maximum permissible voltage of 690 V AC. It cleans up the PWM waveform from the drive output to reduce motor winding stress and bearing currents — a common fix for long cable runs or older motors that don't like the sharp edges of a standard IGBT output. Switching frequency is fixed at 2 kHz, and the filter passes output frequencies up to 70 Hz. That covers most 4-pole induction motor applications up to base speed. The 60 s overload capability of 1.5 x nominal current handles the occasional jog or acceleration transient without oversizing.

That means the BOM line stays stable for new builds and spares alike. No last-time-buy clock ticking on this one.

Mounting is open-chassis (IP00), so it goes inside a panel or enclosure — not a standalone box. Terminal-block electrical connection, no special tooling needed. Thermal losses run 360 W at rated load with a 115 °C hot-spot temperature; plan the enclosure ventilation or derating accordingly. Operating ambient is -10 to 45 °C, storage from -40 to 65 °C. Above 1000 m altitude, derate 1 % per 100 m. Pollution degree 2 per EN 50178 means it's fine for a typical industrial control room or MCC — not for condensing or conductive-dust environments without a sealed cabinet. Shock rated at 15 gn for 11 ms per IEC 60068-2-27, vibration at 1 gn from 13 to 200 Hz with 1.5 mm peak-to-peak below 13 Hz. That's robust enough for most fixed-mount industrial applications; if it's going on a mobile platform or near a large reciprocating compressor, check the actual spectrum against the curve.

Listed to UL 508 — the industrial control equipment standard. That covers the safety and construction requirements for North American panel builds. Humidity tolerance is 0 to 95 % RH non-condensing.

MPN
VW3A5217