Schneider Electric A9C52225

Schneider Electric A9C52225 Reflex iC60N 25A 2P Curve C MCB

MPN A9C52225
Obsolete

Schneider Electric Acti9 Reflex iC60N, integrated control circuit breaker, 25 A, 2P, curve C, 20 kA Icu at 240 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9C52225 specifications
ParameterValue
Trip unit typeThermal-magnetic
Control signal typeMaintained Impulse
Main product or component typeIntegrated control circuit breaker
Coil voltage230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC
Insulation voltage ui500 V AC
IP ratingIP20
Pollution degree3
ColorWhite
Depth77 mm
Width81 mm
Height84 mm
Electrical life cyclesAC-1: 50000 cycles AC 50 Hz
Mechanical life cycles50000 cycles
ApplicationControl Distribution

Product details

The Schneider Electric A9C52225 is a Reflex iC60N integrated control circuit breaker — a 2-pole, 25 A thermal-magnetic MCB with curve C trip characteristic, designed for control and distribution circuits in Acti9 panels. It combines overcurrent protection with local and remote switching capability, accepting control voltages of 230 V AC, 24 V AC, 48 V AC, 24 V DC, or 48 V DC via maintained or impulse signals. Rated breaking capacity reaches 20 kA Icu at 220–240 V AC and 10 kA Icu at 380–415 V AC, per EN/IEC 60947-2 — sufficient for most commercial and light industrial panelboards where fault levels stay within that range. IP20 finger protection covers the terminals per IEC 60529.

No substitute is needed; the Reflex iC60N series remains a standard catalog offering in the Acti9 range.

At 81 mm wide (9 module pitches), the breaker occupies a fixed position on the DIN rail — plan for that footprint in your panel layout. The toggle ON/OFF button and LED local signalling (green ON, red fault, flashing for overheat/trip/ready) give clear status at the panel door without additional indicators. Earth-leakage protection requires a separate Vigi block — not integrated. The control circuit voltage must match your system: 230 V AC is the default, but 24 V AC/DC and 48 V AC/DC options are available on the same unit. Verify the control signal type (maintained or impulse) before wiring.