Schneider Electric A9D17225

Schneider Electric A9D17225 Acti9 iC60 RCBO, 25 A, C-curve,

MPN A9D17225
Active

Schneider Electric Acti9 iC60 RCBO, A9D17225, 2P, 25 A rated current, C-curve, 30 mA earth-leakage sensitivity, 10 kA Icn breaking capacity, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9D17225 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage220...240 V AC 50 Hz
Insulation voltage ui500 V AC 50 Hz
Breaking capacity10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 15 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2
Terminal pitch9 mm between poles
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
ColorWhite

All specifications

A9D17225 additional specifications
ParameterValue
Depth78 mm
Width36 mm
Height86 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

Panel-builder note: A9D17225 Acti9 iC60 RCBO

The Schneider Electric A9D17225 is an Acti9 iC60 RCBO — a combined miniature circuit breaker and residual-current device in a single 36 mm wide, 2-pole module. Clip-on mounting to the DIN rail and tunnel terminals accepting up to 35 mm² rigid conductors make for straightforward panel integration.

The 25 A rating and C-curve suit it for general-purpose branch circuit protection in distribution boards — motor circuits, lighting, socket outlets. The 30 mA earth-leakage threshold provides personal protection against direct contact. Breaking capacity is 10 kA Icn per EN/IEC 61009-2-1 at 220-240 V AC, 50 Hz, with an ultimate breaking capacity (Icu) of 15 kA per EN/IEC 60947-2.

Toggle control with local signalling for ON, OFF, and fault trip. Wire stripping length 12 mm for top or bottom connection; tunnel terminals accept 1-35 mm² rigid or 1-25 mm² flexible. Tightening torque 2 N.m. IP40 in distribution enclosure, IP20 otherwise. Overvoltage category III per IEC 60364. Tropicalisation class 2. Rated for 10,000 electrical and 20,000 mechanical cycles. Humidity tolerance 95% at 55 °C.

MPN
A9D17225