Skip to main content
Schneider Electric A9F04613

Schneider Electric A9F04613 Acti9 iC60N MCB, 13 A, C Curve,

MPN A9F04613
Active

Schneider Electric Acti9 iC60N, miniature circuit breaker, A9F04613, 13 A, C curve, 1P+N, 36 kA breaking capacity, DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F04613 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F04613 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F04613 is an Acti9 iC60N miniature circuit breaker rated at 13 A with a C curve, configured as 1P+N. The dual certification to EN/IEC 60947-2 and EN/IEC 60898-1 means it carries both an industrial (Icu) and a domestic (Icn) breaking capacity rating — 36 kA Icu at 12-60 V AC and 6000 A Icn at 230 V AC, respectively. For a panel builder, the 36 mm width and 78.5 mm depth fit standard enclosure cutouts; the IP20 finger-safe terminals accept up to 25 mm² rigid or 16 mm² flexible conductors.

The C curve (magnetic tripping limit of 8 x In ±20%) means the breaker tolerates moderate inrush currents typical of small motors, transformers, and lighting ballasts without nuisance tripping — a common choice for general-purpose branch circuits. The 13 A rated current (In) is the continuous load the thermal-magnetic trip unit can carry at 30 °C ambient without opening. The thermal-magnetic trip technology combines a bimetal strip for overload protection and a solenoid for short-circuit protection, with no electronic components to fail.

Snap-on DIN rail mounting (per) fits standard 35 mm top-hat rail in enclosures. The toggle control and trip indicator provide local visual status. Strip length is 14 mm for both top and bottom connections. The IP20 degree of protection covers the terminals against finger contact but is not rated for washdown environments.

MPN