Skip to main content
Schneider Electric A9F05125

Schneider Electric A9F05125 Acti9 iC60N MCB, 25 A, 1P, D Cur

MPN A9F05125
Active

Schneider Electric Acti9 iC60N, A9F05125, miniature circuit breaker, 1P, 25 A, D curve, 36 kA breaking capacity at 12-60 VAC, thermal-magnetic trip, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F05125 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2

All specifications

A9F05125 additional specifications
ParameterValue
ColorWhite
Depth78.5 mm
Width18 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F05125 is an Acti9 iC60N miniature circuit breaker — a 1-pole, 25 A, D-curve unit built for distribution boards. The D curve (magnetic trip at 12 x In ±20%) means it handles high inrush loads like motor starters and transformers without nuisance tripping, while the 25 A rated current (In) sets the continuous load ceiling. Breaking capacity is where this part earns its keep: 36 kA Icu at 12-60 VAC and 20 kA at 100-133 VAC per EN/IEC 60947-2, with a 6 kA Icn rating at 230 VAC per EN/IEC 60898-1. That SCCR headroom gives selectivity downstream — a 36 kA fault at the panelboard won't cascade upstream if the fault current stays under that limit. The thermal-magnetic trip unit covers both overload (thermal bimetal) and short-circuit (solenoid) protection in one 18 mm wide package. Mounts on a DIN rail (EN 60715), occupies 2 x 9 mm pitches (18 mm total width), and accepts double terminals top and bottom — rigid up to 25 mm², flexible up to 16 mm². Strip length is 14 mm, torque to 2 Nm.

Integration notes

The 18 mm width and 91 mm height fit standard DIN-rail enclosures; depth of 78.5 mm leaves clearance for gland plates and wiring ducts. The toggle control and trip indicator give local status at a glance. Overvoltage category IV means it's rated for the main distribution board, not just sub-panels.

MPN
A9F05125