Schneider Electric A9F07420

Schneider Electric A9F07420 Acti9 iC60H MCB, 20A 4P C-Curve

MPN A9F07420
Active

Schneider Electric Acti9 iC60H, A9F07420, miniature circuit breaker, 4P, 20 A, C-curve, 42 kA breaking capacity, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F07420 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F07420 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F07420 is an Acti9 iC60H miniature circuit breaker rated for 20 A with a C-curve trip characteristic, four protected poles, and a breaking capacity that hits 42 kA Icu at 12–133 V AC and 30 kA at 220–240 V AC. It's a thermal-magnetic MCB built to dual standards — EN/IEC 60947-2 for industrial use and EN/IEC 60898-1 for residential/commercial — so it fits distribution boards and panel schedules where both certifications matter. The 42 kA figure at low voltage means it can handle serious fault currents upstream without letting an arc cascade through the panel.

The C-curve (magnetic trip at 8 x In ±20%) means this breaker holds through moderate inrush — typical for lighting banks, small transformers, and motor control circuits where the start-up surge doesn't exceed about 160 A before the magnetic trip clears a hard short. At 400 V AC, the Icn (rated short-circuit capacity per EN/IEC 60898-1) is 10 kA, while the Icu per 60947-2 is 15 kA at 380–415 V and 10 kA at 440 V. That 15 kA at 400 V-class voltages is enough for most sub-distribution panels fed by a 500 kVA transformer; if your available fault current is higher, step up to the iC60L or a molded-case breaker.

The IP20 finger-safe terminals accept 1–25 mm² rigid or 1–16 mm² flexible wire, double-terminals top and bottom for daisy-chaining feed-through. The toggle handle and trip indicator give a clear visual on the panel front.