Skip to main content
Schneider Electric A9F08404

A9F08404 Acti9 iC60H D-Curve MCB, 4A 4P 70kA

MPN A9F08404
Obsolete

Schneider Electric Acti9 iC60H miniature circuit-breaker, A9F08404, 4A rated current, 4 poles, D-curve, 70kA Icu at 415V AC, DIN rail mount, thermal-magnetic trip.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F08404 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity70 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F08404 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F08404 is a Schneider Electric Acti9 iC60H miniature circuit-breaker (MCB) rated at 4 A with 4 protected poles and a D tripping curve. It is a thermal-magnetic device for distribution applications, mountable on a DIN rail (9 mm pitch, 8 modules wide). Breaking capacity reaches 70 kA Icu at 380-415 V AC (50/60 Hz) per EN/IEC 60947-2, and 10 kA Icn at 400 V per EN/IEC 60898-1. This dual rating lets you use it in industrial panels (60947-2) or final-distribution boards (60898-1) without re-specifying.

Panel builders should account for the 78.5 mm depth behind the mounting surface when sizing gland plates or enclosure depth. Terminals accept 1-25 mm² rigid or 1-16 mm² flexible wire (double terminal top and bottom). The IP20 finger-safe front allows live panel access for troubleshooting.

Dual-certified to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (household/residential). Suitability for isolation is confirmed under both standards. Pollution degree 3, overvoltage category IV, and IP20 protection. The trip indicator provides local visual signalling of the breaker state without needing a multimeter.

MPN
A9F08404