Specifications

A9F08406 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F08406 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F08406 is an Acti9 iC60H miniature circuit breaker with a D tripping curve, rated 6 A, 4 poles, and a breaking capacity of 42 kA Icu at 12-133 V AC. The D curve means the magnetic trip is set at 12 x In +/- 20 %, so it handles high inrush currents from motor or transformer loads without nuisance tripping — that's the main reason you'd pick this over a B or C curve in the same iC60 family.

The 4-pole unit occupies 8 x 9 mm pitches (72 mm wide). Terminals accept 1-25 mm² rigid or 1-16 mm² flexible wire; strip length is 14 mm.

Tropicalisation class 2 per IEC 60068-1 means it withstands 95 % relative humidity at 55 °C. The thermal-magnetic trip unit delivers 10,000 electrical cycles and 20,000 mechanical cycles. Isolation suitability is confirmed per both standards, and a contact position indicator is built in.