Specifications

A9F43370 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage12...133 V AC 50/60 Hz 220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 440 V AC 50/60 Hz <= 180 V DC
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F43370 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width54 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
Operating temperature-35...70 °C

Product details

The A9F43370 is a Schneider Electric Acti9 iC60N miniature circuit breaker rated 0.5 A with a B curve, meaning the magnetic trip fires at 4 x In (2 A) within a ±20% tolerance — suited for resistive or lightly inductive loads where nuisance tripping from inrush is a concern. Three poles protected, so it switches all three phases in a 3P AC/DC network. The 50 kA Icu at 415 V AC is the ultimate breaking capacity under IEC 60947-2; for domestic-grade coordination under IEC 60898-1, the Icn is 6 kA at 400 V. That dual rating tells you this MCB is rated for industrial panel duty (60947-2) while still carrying the residential standard mark. Clip-on mounting on a DIN rail, 54 mm wide (6 x 9 mm pitches), 85 mm tall, 78.5 mm deep — fits standard distribution boards and sub-panels. IP20 finger-safe terminals; the toggle provides local trip indication and is padlockable for lockout/tagout.