Skip to main content
Schneider Electric A9F45425

Schneider Electric A9F45425 iC60N MCB, D Curve, 25 A, 4P, 36

MPN A9F45425
Obsolete

Schneider Electric Acti9 iC60N, miniature circuit-breaker, A9F45425, 4P, 25 A, D curve, 36 kA breaking capacity, clip-on rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F45425 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage12...133 V AC 50/60 Hz 220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 440 V AC 50/60 Hz <= 250 V DC
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F45425 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
Operating temperature-35...70 °C

Product details

The A9F45425 is a Schneider Electric Acti9 iC60N miniature circuit breaker — 4 poles, 25 A rated current, D curve, thermal-magnetic trip. Breaking capacity reaches 36 kA Icu at 12…133 V AC, 20 kA at 220…240 V, and 10 kA at 380…415 V (all per IEC 60947-2); under IEC 60898-1 it carries 10 kA Icn at 415 V. That dual rating means it qualifies for both industrial (60947-2) and residential/commercial (60898-1) installations — useful when a panel crosses classification boundaries. Terminal accepts 1…25 mm² rigid or 1…16 mm² flexible; torque to 2 N·m. The 78.5 mm depth keeps it flush with other Acti9 devices in a row — no overhang on the enclosure door.

Snap-on DIN-rail mounting inside a distribution board or industrial control panel. The 4-pole configuration handles three-phase plus neutral (or three-phase switched with a fourth pole for an additional phase). Pollution degree 3 (conductive pollution, typical in industrial enclosures) and tropicalisation class 2 per IEC 60068-1 mean it tolerates humidity up to 95 % at 55 °C without derating — suited for non-conditioned plant rooms or outdoor-rated enclosures.

Coordination and selectivity note

The separate earth-leakage block (Vigi iC60) clips onto the same busbar stack if ground-fault protection is required, without changing the breaker footprint.

MPN
A9F45425