Skip to main content
Schneider Electric A9F45470

A9F45470 Acti9 iC60N MCB, 4P D-curve 0.5A, 50kA

MPN A9F45470
Obsolete

Schneider Electric Acti9 iC60N, A9F45470, 4-pole miniature circuit breaker, D-curve, 0.5 A, 50 kA breaking capacity at 415 V AC, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F45470 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage12...133 V AC 50/60 Hz 220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 440 V AC 50/60 Hz <= 250 V DC
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F45470 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
Operating temperature-35...70 °C

Product details

The A9F45470 is a 4-pole Acti9 iC60N miniature circuit breaker (MCB) with a D-curve and a 0.5 A rated current. It clips onto a DIN rail (mounting support: rail, clip-on) and takes up 8 x 9 mm pitches (72 mm wide, 85 mm high, 78.5 mm deep), so you can plan the panel layout precisely. The D-curve means magnetic tripping occurs at 12 x In ±20 % — that is, between roughly 4.8 A and 7.2 A — which suits loads with a high inrush, like small transformers or solenoid valves, not general lighting or resistive heaters. Breaking capacity is the number that decides whether it clears a fault without welding contacts or blowing up the panel. This unit delivers 50 kA Icu at 220…240 V AC and at 380…415 V AC (per EN/IEC 60947-2), and 10 kA Icn at 415 V AC (per EN/IEC 60898-1). The 25 kA Icu at 440 V AC is still high for a 0.5 A frame. The thermal-magnetic trip unit handles the two fault regimes: thermal (overload, slow) and magnetic (short-circuit, instantaneous). The IP20 rating (finger-safe terminals) means it belongs inside a closed panel, not exposed to washdown.

For a buyer filling a BOM line: the 0.5 A rating is the unusual spec here — most iC60N breakers start at 1 A or higher. That low current, combined with the D-curve and 4-pole format, makes this a niche part that may not sit on every distributor's shelf.

MPN