Skip to main content
Schneider Electric A9F68204

Schneider Electric A9F68204 Acti9 iT60 MCB, C-Curve 4 A 2P,

MPN A9F68204
Active

Schneider Electric Acti9 iT60, A9F68204, miniature circuit breaker, 4 A, C-curve, 2P, 50 kA Icu at 400 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F68204 specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Width36 mm
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F68204 is an Acti9 iT60 miniature circuit breaker rated at 4 A with a C-curve magnetic trip (8 x In ±20 %), 2-pole configuration, and a 50 kA ultimate breaking capacity (Icu) at 380–415 V AC per EN/IEC 60947-2. It also carries a 10 kA Icn rating at 400 V AC per EN/IEC 60898-1, so it meets both the higher-fault industrial standard and the residential/commercial standard on the same device — useful when a panel must satisfy both a utility requirement and an internal plant spec. The C-curve means the magnetic trip activates between 5 and 10 times the rated current (here 8 x In ±20 %), making it the standard choice for general distribution circuits feeding mixed resistive and moderate inductive loads — lighting, socket outlets, small motor starters — where inrush isn't severe enough to need a D curve but a B curve would nuisance-trip on start-up.

Snaps onto a DIN rail (mounting support: DIN rail per) and occupies 36 mm width (4 x 9 mm pitches). The removable comb busbar is installed from the factory, so busbar alignment is pre-set — no fiddling with loose bridges on site. Terminals accept 1–25 mm² rigid or 1–16 mm² flexible, with a 2 N·m tightening torque and 14 mm strip length.

Rated for operation from -35 °C to 70 °C ambient, storage from -40 °C to 85 °C, with 95 % relative humidity tolerance and tropicalisation level 2 per EN/IEC 60068-2-78. Overvoltage category IV suits it for main distribution board installation, not just sub-circuits.

MPN