Skip to main content
Schneider Electric A9MEM3255-NMI

Schneider Electric A9MEM3255-NMI Acti9 iEM3255 Energy Meter,

MPN A9MEM3255-NMI
Active

Schneider Electric Acti9 iEM3000 series, iEM3255 energy meter, 0.5S accuracy class, 4-quadrant active/reactive energy metering, RS485 Modbus, 3P+N, clip-on DIN rail, 90 x 95 x 69 mm, white.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9MEM3255-NMI specifications
ParameterValue
Input typeCurrent transformer 1 A or 5 A
Display typeLCD display
Main product or component typeEnergy meter
Voltage5...40 V DC@50 mA
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree2
ColorWhite
Depth69 mm
Width90 mm
Height95 mm
ApplicationMulti-tariff Partial meter Sub billing
I/O channels1 digital 0...5 V/11...40 V 24 V DC
Operating temperature-25...70 °C - IEC

Product details

The meter measures current from 1 mA up to 32.767 A secondary, which covers the full dynamic range from light-load office floors to near-full-ratio CT saturation. Rated current is 5 A or 1 A, matching the CT secondary you feed it. Sampling at 32 samples per cycle gives decent harmonic content capture up to the 15th or so — enough for general power quality awareness, though not a full PQ analyzer. The LCD display scrolls through active power, reactive power, voltage, current, and accumulated energy, so a field tech can read real-time values without a comms tool. Four tariff inputs let the meter switch between four rate registers via dry-contact or voltage signals, so a single meter handles time-of-use billing without an external controller. The RS485 Modbus port reports all registers to a BMS or energy management system — wiring is via screw terminals, 2.5 mm² for voltage and 6 mm² for current circuits. The digital output is a static pulse output configurable for kWh or kvarh, driving 5…40 V DC at up to 50 mA — enough to feed a remote pulsecounter or PLC input. The digital input accepts 0…5 V or 11…40 V DC for external tariff switching or reset.

Height is 95 mm, depth 69 mm. Operating altitude below 3000 m, relative humidity 5…95% at 50 °C. The green LED shows power on; a yellow flashing LED signals accuracy checking or overload alarm; a yellow steady LED indicates Modbus activity.

MPN
A9MEM3255-NMI