Skip to main content
Schneider Electric A9N18344

A9N18344 Acti9 C120N MCB, 63 A, B Curve, 2P, 10 kA

MPN A9N18344
Active

Schneider Electric Acti9 C120N miniature circuit breaker, A9N18344, 63 A, B curve, 2 poles, 10 kA Icn at 400 V AC, thermal-magnetic trip, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N18344 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage380...415 V AC 50/60 Hz 220...240 V AC 50/60 Hz 440 V AC 50/60 Hz 230...400 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C

All specifications

A9N18344 additional specifications
ParameterValue
Pollution degree3 conforming to IEC 60947-2
ColorWhite
Depth73 mm
Width54 mm
Height81 mm
Electrical life cycles10000 cycles conforming to IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric A9N18344 is an Acti9 C120N miniature circuit breaker rated 63 A at 30 °C, B curve, 2-pole, with a 10 kA Icn breaking capacity at 400 V AC per EN/IEC 60898-1. It also carries a 6 kA Icu rating at 440 V AC and 10 kA Icu at 380–415 V AC per EN/IEC 60947-2, which governs its use in industrial distribution panels where the higher fault-current headroom matters.

The B curve means the magnetic trip fires between 3 and 5 times In — so for a 63 A breaker, instantaneous trip starts around 189 A and is guaranteed by 315 A. The 60947-2 rating of 10 kA Icu at 380–415 V AC gives you the fault-clearing confidence for a 400 V distribution board feeding downstream sub-circuits. Thermal-magnetic trip technology means it uses a bimetal strip for overload protection and a solenoid for short-circuit — no electronics to fail, no auxiliary power needed. The 63 A rating at 30 °C is the baseline; expect derating at higher ambient temperatures inside a crowded enclosure.

The tunnel-type terminals accept 1–50 mm² rigid or 1.5–35 mm² flexible cable; strip 15 mm and torque to 3.5 N·m. Neutral is on the left, poles are protected, and the toggle gives clear ON/OFF indication. IP20 finger-safe front, so it lives inside an enclosure — not in a washdown zone.

MPN