Skip to main content
Schneider Electric A9N18371

Schneider Electric A9N18371 Acti9 C120N MCB, 63 A, 4P, C-Cur

MPN A9N18371
Active

Schneider Electric Acti9 C120N, miniature circuit breaker, 63 A, 4P, C-curve, 10 kA Icn at 400 V AC, thermal-magnetic trip, clip-on DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N18371 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage380...415 V AC 50/60 Hz 220...240 V AC 50/60 Hz 440 V AC 50/60 Hz 230...400 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at <= 500 V DC conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C

All specifications

A9N18371 additional specifications
ParameterValue
Pollution degree3 conforming to IEC 60947-2
ColorWhite
Depth73 mm
Width108 mm
Height81 mm
Electrical life cycles10000 cycles conforming to IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The A9N18371 is a 4-pole miniature circuit breaker from the Acti9 C120N series, rated 63 A at 30 °C with a C-curve (magnetic trip 5...10 x In). That C-curve means it handles moderate inrush — typical for general distribution loads like lighting, socket circuits, and light motor feeders — without nuisance tripping on startup. The 10 kA Icn at 400 V AC (EN/IEC 60898-1) and 6 kA Icu at 440 V AC (EN/IEC 60947-2) tell you the fault-clearing capacity under different standards: the Icn is the rated short-circuit capacity for MCB duty, while the Icu is the ultimate breaking capacity for industrial use.

Clip-on mounting on a 35 mm symmetrical DIN rail, 12 module pitches wide (108 mm). The 73 mm depth leaves clearance for standard enclosure depths — no need for a deep gland plate. Tunnel terminals accept 1...50 mm² rigid or 1.5...35 mm² flexible; torque to 3.5 N·m. IP20 finger-safe front, so it's fine inside a panel but not for wet locations.

Current-production status confirmed. For a BOM-freeze item, this is a low-risk line — no LTB clock ticking.

MPN
A9N18371