A9N19534 Acti9 DPN Vigi 16A C Curve RCBO, 30mA

MPN A9N19534
Obsolete

Schneider Electric Acti9 DPN Vigi RCBO, 16 A rated current, C curve, 30 mA earth-leakage sensitivity, 4500 A breaking capacity, 1P+N, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N19534 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage220...240 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz
Breaking capacity4500 A Icn at 220...240 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Terminal pitch9 mm between phase and neutral
Temp storage max70 °C
Temp storage min-30 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-30...70 °C
Pollution degree3

All specifications

A9N19534 additional specifications
ParameterValue
ColorWhite
Depth77.5 mm
Width36 mm
Height81 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

Breaking capacity is 4500 A Icn at 220–240 V AC, 50/60 Hz, per EN/IEC 61009-2-1.

The C curve means the magnetic trip operates between 5 and 10 times rated current — so 80 to 160 A for this 16 A unit. That's a good fit for motor-starting or transformer inrush where you don't want nuisance trips on a brief surge. The 30 mA earth-leakage threshold is the standard for personal protection (IEC 60364 recommends it for socket-outlet circuits). The thermal-magnetic trip unit handles the overload side; the integrated residual current module handles the ground-fault side. Both in one package saves a DIN rail slot compared to a separate MCB + RCCB. The IP20 body is fine inside an enclosure; the modular enclosure gets IP40 once installed. Connection pitch is 9 mm between phase and neutral, so the tunnel terminals line up cleanly on a standard DIN-rail busbar.

Neutral is on the left, phase on the right — standard for Acti9 DPN Vigi. Tunnel terminals accept 0.75–16 mm² rigid or 0.33–10 mm² flexible; strip length 15 mm, tighten to 2 N·m. The toggle gives clear ON/OFF/fault-trip local signalling, so you can see at a glance whether it's a trip or a manual shutdown.