Schneider Electric A9N19645

Schneider Electric A9N19645 Acti9 DPN Vigi RCBO, 20A C-Curve

MPN A9N19645
Obsolete

Schneider Electric Acti9 DPN Vigi, RCBO, 1P+N, 20 A, C-curve, 300 mA earth leakage, Type A-SI (Super Immunised), 6 kA breaking capacity.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N19645 specifications
ParameterValue
Control typeToggle
Product typeType A-SI (Super Immunised)
Trip unit typeThermal-magnetic
Main product or component typeEarth leakage circuit breaker
Voltage230 V AC
Insulation voltage ui400 V AC conforming to EN 61009
Breaking capacity6000 A Icn at 230 V AC conforming to EN 61009
Temp storage max60 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...60 °C
Pollution degree3 conforming to EN 61009
ColorWhite
Electrical life cycles20000 cycles conforming to IEC 61009
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

The Type A-SI (Super Immunised) designation means the RCD element is designed to resist nuisance tripping from high-frequency leakage currents generated by modern electronic loads like VFDs, LED drivers, and UPS equipment — a practical choice for mixed-load outgoing circuits.

The 20 A rated current at 30 °C sets the continuous thermal capacity for resistive and mixed loads; the C-curve (5–10 x In) means the magnetic trip releases between 100 A and 200 A for short-circuit faults, which is the standard choice for general-purpose distribution circuits feeding socket outlets and small appliances. The 300 mA earth-leakage sensitivity is a delayed-action or high-threshold RCD intended for protection against fire risk from earth faults, not direct personal shock protection (which requires 30 mA or lower). This makes the A9N19645 suitable for circuits supplying fixed equipment where 30 mA nuisance tripping is a concern — think lighting banks, air-handling units, or commercial kitchen appliances — while still providing ground-fault detection. The integrated earth-leakage protection is instantaneous (no intentional time delay), so it will coordinate with upstream time-delayed S-type RCDs in a selective scheme. The thermal-magnetic trip unit is the standard dual-element design: a bimetal strip handles overload protection (inverse time curve), and a solenoid coil handles short-circuit protection (instantaneous above the C-curve threshold). The 20,000-cycle electrical durability and matching mechanical durability (conforming to IEC 61009) reflect a solidly built device rated for typical switching duty in distribution — not a high-cycling contactor application, but fine for the occasional manual isolation or fault interruption over its service life.

The 1P+N configuration (neutral left, phase right) is the standard arrangement for single-phase outgoing circuits in European-style distribution boards. Tunnel-type terminals accept up to 10 mm² flexible or 16 mm² rigid cable, which covers the full range of conductor sizes for a 20 A circuit. Embedding depth of 72 mm fits standard shallow enclosures. The toggle control provides local ON/OFF indication and manual switching; the contact position indicator confirms the state of the main contacts independently of the toggle mechanism — useful for lockout/tagout verification during panel maintenance.

Tropicalisation level 2 conforming to EN 61009 indicates the device is treated to resist humidity and fungal growth — relevant for installations in coastal or high-humidity environments. Certified to EN/IEC 61009-1 and EN/IEC 61009-2-1, the harmonized standards for RCBOs in Europe. Limitation class 3 (energy-limiting performance) means the device restricts the let-through energy during a short-circuit fault, reducing stress on downstream wiring and connected equipment.