Skip to main content
Schneider Electric A9N1P16CGN

Schneider Electric A9N1P16CGN Acti9 xC60 MCB, 16A, 1P, C-Cur

MPN A9N1P16CGN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, A9N1P16CGN, 1P, 16 A, C-curve, 10 kA breaking capacity at 240 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N1P16CGN key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage220...240 V AC 50/60 Hz
Breaking capacity10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9N1P16CGN additional specifications
ParameterValue
ColorWhite
Depth77.5 mm
Width18 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The Schneider Electric A9N1P16CGN is an Acti9 xC60 miniature circuit breaker — 1-pole, 16 A rated current, C-curve trip characteristic. It clips onto a 35 mm DIN rail, occupying two 9 mm pitches (18 mm wide). The thermal-magnetic trip unit handles distribution circuits in residential and light commercial panels, with a breaking capacity of 10,000 A Icn at 240 V AC per IS/IEC 60898-1. That rating means it can safely interrupt a fault current up to 10 kA without welding contacts or cascading failure upstream.

What the ratings mean for your panel

The C-curve (magnetic trip 5...10 × In) is the standard choice for general-purpose distribution — it handles inrush from small motors, transformers, and lighting ballasts without nuisance tripping, while still clearing short-circuit faults fast enough for cable protection. The 16 A rating on a 1-pole breaker suits final subcircuits feeding socket outlets, lighting, or small equipment on a 220–240 V AC network. Pollution degree 3 and overvoltage category IV mean the breaker is rated for the harsh conditions inside a distribution board — conductive dust, humidity, and direct connection to the mains supply where transient overvoltages can reach several kV. The tropicalisation treatment (2 conforming to IEC 60068-1) adds resistance to heat and humidity cycling, so this MCB holds up in non-conditioned environments. IP20 protection on the front means it is touch-safe for the panel interior but not rated for wet or outdoor exposure. The tunnel-type terminals accept up to 25 mm² rigid or 16 mm² flexible cable; the biconnect feature allows daisy-chaining without pigtails. Tightening torque is 2 N·m — a standard value for this terminal class, no special tool needed.

MPN
A9N1P16CGN