Skip to main content
Schneider Electric A9N21490

Schneider Electric A9N21490 Vigi TG40 RCD, 25A 30mA 3P+N

MPN A9N21490
Obsolete

Schneider Electric Prodis Vigi TG40 add-on residual current device, 3P+N, 25 A rated current, 30 mA earth-leakage sensitivity, Type AC, voltage-independent trip, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N21490 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage400 V AC 50 Hz phase to phase
Insulation voltage ui400 V AC 50 Hz conforming to EN 61009-1
IP ratingIP20
Temp storage max60 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...60 °C
Pollution degree3 conforming to EN 61009-1
ColorWhite
Depth70 mm
Width54 mm
Height82 mm
Operating temperature-5...60 °C

Product details

It is a 3P+N block that clips onto the downstream side of a compatible Prodis MCB via screw terminals, adding earth-leakage protection to the group incomer position in a DIN-rail panel. Rated at 25 A (In) with 30 mA sensitivity, Type AC earth-leakage protection, and instantaneous trip. The voltage-independent trip mechanism means it operates without needing an external power supply — it draws its trip energy from the fault current itself. Certified to IEC 60947-2, EN 61009-1, and EN 61009-2-1. Pollution degree 3 per EN 61009-1, impulse withstand voltage 6 kV (Uimp), and tropicalisation class 2 per IEC 60068-1 — suitable for controlled indoor environments with high humidity (95% at 55 °C).

The 25 A rated current and 30 mA sensitivity are the key specs. The 25 A In matches the upstream MCB rating — this RCD block is sized for a group incomer. Type AC detection means it trips on sinusoidal AC residual currents only. Rated operational voltage 400 V AC phase-to-phase, 50 Hz. Insulation voltage 400 V AC. The 3P+N configuration with neutral on the left (viewed from the front) must be observed when wiring — reversing the neutral and a phase compromises the trip coil supervision. Clip-on mounting to DIN rail, 6 module pitches wide (54 mm). IP20 finger-safe front, but the terminals require live-work precautions when the enclosure door is open.

MPN