Schneider Electric A9N60781 Acti9 C120H MCB, 2P, 80 A, C-Cur

MPN A9N60781
Obsolete

Schneider Electric Acti9 C120H miniature circuit breaker, 2P, 80 A, C-curve, 15 kA Icu at 230...400 V AC, EN/IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N60781 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage230...400 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity15 kA Icu at 15 kA Icu at 230...400 V AC 50/60 Hz conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C

All specifications

A9N60781 additional specifications
ParameterValue
Pollution degree3 conforming to IEC 60947-2
ColorWhite
Depth73 mm
Width54 mm
Height81 mm
Electrical life cycles5000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The Schneider Electric A9N60781 is a 2-pole Acti9 C120H miniature circuit breaker rated 80 A at 40 °C, with a C-curve (magnetic trip at 8 x In ±20 %). Its 15 kA Icu breaking capacity at 230...400 V AC 50/60 Hz means it can safely interrupt fault currents up to that level without upstream damage — sized for distribution panels where the prospective short-circuit current is known to stay under 15 kA. IP20 finger-safe terminals accept rigid conductors up to 50 mm² or flexible up to 35 mm², with a tunnel-type terminal tightened to 3.5 N·m. The handle seals in OFF or ON position with a 0.7 mm cable for lockout/tagout compliance.

Integration notes

Dimensions: 81 mm high, 54 mm wide, 73 mm deep — fits standard 35 mm DIN rail with 6 module spaces. Wire stripping length is 15 mm; the tunnel terminal accepts solid 1...50 mm² or flexible 1.5...35 mm². Rated insulation voltage 500 V AC, operational voltage 230...400 V AC. The breaker is rated for 5000 electrical cycles and 20000 mechanical cycles — sufficient for distribution duty where switching is infrequent. Separate earth-leakage protection block available if needed (not integrated).

MPN