Schneider Electric A9R14263

Schneider Electric A9R14263 Acti9 iID RCCB, 63 A, 300 mA

MPN A9R14263
Obsolete

Schneider Electric Acti9 iID, A9R14263, 2P residual current circuit breaker (RCCB), 63 A, 300 mA, Type AC, voltage independent, instantaneous, clip-on DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9R14263 specifications
ParameterValue
Control typeToggle
Voltage220...240 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...85 °C
Pollution degree3
ColorWhite
Depth73.5 mm
Width36 mm
Height91 mm
Electrical life cyclesAC-1: 15000 cycles
Mechanical life cycles20000 cycles
Operating temperature-5...60 °C

Product details

The Schneider Electric A9R14263 is a 2-pole residual current circuit breaker (RCCB) from the Acti9 iID family, rated 63 A continuous current with 300 mA earth-leakage sensitivity. The tripping is voltage independent, so it clears a ground fault even if the line voltage collapses.

The breaking capacity is 1500 A (Idm and Im both 1500 A), which covers most sub-distribution fault levels; if your upstream breaker can deliver more, you'll need to check coordination. The insulation voltage is rated 500 V AC, so the internal clearances are good for a 277/480 V system if you're using it in a delta or corner-grounded configuration (but the coil is still 240 V). Earth-leakage protection is instantaneous — no intentional time delay. That means it trips as soon as the residual current exceeds 300 mA, which is fine for general shock protection (the 300 mA threshold is typical for fire protection or equipment ground-fault, not personnel shock — personnel protection usually calls for 30 mA). The 8/20 µs impulse withstand of 250 A means it won't nuisance-trip on lightning surges or switching transients up to that energy level.

Durability and environmental fit

Mechanical durability is 20,000 cycles; electrical durability under AC-1 (resistive load) is 15,000 cycles — that's a solid service life for a distribution board that doesn't see daily switching. The operating temperature range is -5 to 60 °C, and storage from -40 to 85 °C, so it's fine in an unheated enclosure as long as the ambient stays above -5. IP20 on the terminals, IP40 inside a modular enclosure — keep it behind a panel door or in a cabinet; it's not rated for washdown.

MPN
A9R14263