Skip to main content
Schneider Electric A9Y74725

Schneider Electric A9Y74725 Acti9 Vigi iCG40 RCD, 25A 30mA 4

MPN A9Y74725
Active

Schneider Electric Acti9 Vigi iCG40 add-on residual current device, A9Y74725, 25 A rated, 30 mA sensitivity, Type A-SI (Super Immunised), 3P+N, 400 V AC, DIN rail clip-on.

$314.17 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9Y74725 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage400 V AC 50/60 Hz
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 61009-2-1
ColorWhite
Depth74 mm
Width108 mm
Height99.5 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

The Schneider Electric A9Y74725 is an Acti9 Vigi iCG40 add-on residual current device (RCD) — a voltage-independent, instantaneous-trip unit rated 25 A with 30 mA earth-leakage sensitivity. It clips onto the outgoing side of a compatible Acti9 MCB via screw terminals, adding ground-fault protection to a 3P+N circuit at 400 V AC. The 30 mA sensitivity covers personnel protection (hand-to-hand or hand-to-ground fault paths) per IEC 61009-2-1. Type A-SI (Super Immunised) means it rejects nuisance tripping from pulsed DC loads, variable-speed drives, and UPS systems — common in modern panels where standard Type A or AC RCDs would false-trip on leakage harmonics. Rated operational voltage is 400 V AC at 50/60 Hz, insulation voltage 440 V AC, impulse withstand 4 kV. Pollution degree 3 (conductive or dry non-conductive pollution) fits industrial control enclosures where condensation or light dust is expected.

Clip-on mounting to DIN rail, 108 mm wide (6 x 9 mm pitches), 74 mm deep, 99.5 mm tall. The neutral position is left; the device connects to the upstream MCB by screws. Tunnel terminals accept 1…16 mm² rigid or 1…10 mm² flexible, with a 14 mm strip length and 2 N·m tightening torque. IP20 on the device body, IP40 inside a modular enclosure. Ambient operating range -25…60 °C, storage -40…85 °C, with 95 % RH at 55 °C. Maximum operating altitude 2000 m. Electrical durability 10,000 cycles, mechanical 20,000 cycles.

MPN
A9Y74725