Skip to main content
Schneider Electric ABE7S16E2B1E

Schneider ABE7S16E2B1E Solid State Relay Sub-base, 16 Inputs

MPN ABE7S16E2B1E
Active

Schneider Modicon ABE7 series, solid state input relay sub-base ABE7S16E2B1E, 16 inputs, 24 V DC, 12 mA per channel, ≤0.4 ms response, DIN-rail or screw-mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ABE7S16E2B1E specifications
ParameterValue
Terminal block typeRemovable
Insulation voltage ui2000 V
Frequency<= 1000 Hz duty cycle: 50 %
IP ratingIP2X
Response time<= 0.4 ms from state 1 to 0
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...80 °C conforming to IEC 61131-2
Pollution degreePollution degree 2
Channels16
Operating temperature-5...60 °C conforming to IEC 61131-2

Product details

The ABE7S16E2B1E is a Modicon ABE7 solid-state input relay sub-base — 16 channels, each rated at 12 mA, switching at ≤0.4 ms from state 1 to 0. It sits between a 24 V DC sensor bank and the PLC input card, isolating the PLC side from the field wiring. The 12 mA per channel tells you this is for low-side discrete sensing (proximity, limit switches, photo-eyes), not for driving loads directly. Input characteristics follow IEC 61131-2 Type 1 — the standard threshold for 24 V DC digital inputs. State 1 guaranteed at ≥15 V on the sensor end; state 0 guaranteed at ≤2 mA. That means a standard 3-wire proximity sensor with a 2 mA dark current will reliably register OFF.

The removable spring-terminal block accepts 0.14 to 2.5 mm² solid or 0.09 to 1.5 mm² flexible with ferrule — standard for control-panel wiring. Two terminals per channel give you a dedicated return path per sensor, which helps keep the wiring tidy and the common rail clean. Internal 1 A fast-blow 5×20 mm fuse protects the PLC-end side; the sensor-end side expects an external fast-blow fuse sized to the loop. The IP2X housing is splash-resistant but not washdown-rated — keep it inside the enclosure.

Lifecycle reality — obsolete

Schneider lists this part as obsolete. No official successor order code appears on record.

The 12 mA per channel is the key fit constraint. If your sensors draw more than 12 mA steady-state (some old inductive proxes pull 20–30 mA), this sub-base won't support them — you'd need a higher-current input module. The ≤0.4 ms response is fast enough for most discrete sensing at conveyor speeds under 2 m/s; for high-speed counting or cam-timing applications, you'd want something in the ≤0.1 ms range. Pollution degree 2 (non-conductive, occasional condensation) and installation category II (fixed equipment with transient overvoltage protection downstream of the main panel) are standard for control cabinets. The 2.5 kV impulse withstand and 2000 V dielectric strength give you enough headroom for 480 VAC panels with proper isolation.

MPN
ABE7S16E2B1E