Skip to main content
Schneider Electric ATH650U55N4

Schneider ATH650U55N4 Altivar HVAC Drive, 5.5 kW, 7.5 hp

MPN ATH650U55N4
Active

Schneider Electric Altivar HVAC ATH600 series, ATH650U55N4, 5.5 kW / 7.5 hp variable frequency drive, 380-480 V, wall mount, 254 x 189 x 375 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATH650U55N4 specifications
ParameterValue
Connector typeRJ45 and open style terminals
Main product or component typeVariable speed drive
Current9.331 A at 380 V (normal duty) 8.1 A at 480 V (normal duty) 7 A at 380 V (heavy duty) 6 A at 480 V (heavy duty)
Horsepower7.5 hp for normal duty 5 hp for heavy duty
Frequency50...60 Hz - 5...5 %
IP ratingIP55
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max50 °C
Temp operating min-15 °C
Storage temperature-40...70 °C
Pollution degree2
Depth254 mm
Width189 mm
Height375 mm
Data format8 bits, configurable odd, even or no parity 8 bits, no parity, 1 stop
Operating positionVertical position

Product details

The Schneider ATH650U55N4 is an Altivar HVAC drive sized for a 5.5 kW (7.5 hp) motor at 380-480 V three-phase. Normal duty line current is 9.331 A at 380 V; heavy duty drops to 7 A at 380 V, so the motor load curve dictates which rating applies. Integrated Class C2 EMC filter covers most commercial installations without an external box. Wall-mount format — 254 mm deep, 189 mm wide, 375 mm tall — fits a standard panel backplate.

Controls and fieldbus

Standard RS-485 port runs Modbus RTU or BACnet MS/TP at selectable baud rates up to 76.8 kbit/s. Optional communication cards add BACnet IP, PROFINET, or Ethernet IP/Modbus TCP. The control supply is 24 V DC (19...30 V external); internal supplies handle digital inputs, STO, and a 10.5 V reference for the potentiometer. Six digital inputs, two analog inputs, two analog outputs, and three relay outputs cover basic HVAC sequencing without an I/O extension.

Application functions

Built-in PID controller with three additional PID sets, fire mode, forced fire mode, damper control, scroll compressor management, underload detection for broken belt, catch on the fly, and power monitoring. These are not optional firmware — they are standard on this variant. Sampling times for digital inputs are 2 ms + 0.5 ms; analog inputs sample at 5 ms + 1 ms, adequate for HVAC pressure and temperature loops.

MPN
ATH650U55N4