Skip to main content
Schneider Electric ATV6A0C20S6

Schneider ATV6A0C20S6 Altivar Process ATV600, 200 HP Drive

MPN ATV6A0C20S6
Active

Schneider Electric Altivar Process ATV600, modular VFD, ATV6A0C20S6, 200 hp at 600 V normal duty, 175 hp heavy duty, integrated EMC filter C3, STO SIL3.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV6A0C20S6 specifications
ParameterValue
Main product or component typeVariable speed drive
Current172.0 A 600 V normal duty) 152.0 A 600 V heavy duty)
Horsepower200.0 hp at 600 V normal duty 175.0 hp at 600 V heavy duty
Frequency50...60 Hz - 5...5 %
IP ratingUL type 1 conforming to UL 61800-5-1 (cabinet integration)
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min1.1 °C
Storage temperature-40...158 °F (-40...70 °C)
Pollution degreePollution degree 2
Data format8 bits, configurable odd, even or no parity Modbus serial
Operating temperature14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor

Product details

Drive at a glance

The ATV6A0C20S6 is a modular Altivar Process ATV600 drive rated for 200 hp at 600 V normal duty and 175 hp heavy duty, drawing 172 A and 152 A line current respectively. It ships in cabinet-mount form with forced-convection cooling and carries CE marking alongside UL 61800-5-1 Type 1 protection for cabinet integration.

Ratings and real-world derating

Switching frequency is adjustable 2–4.9 kHz with a derating factor, so plan for reduced output current if you run above 4 kHz. Operating altitude is limited to 2000 m with derating above 1000 m. The prospective line short-circuit current rating is 50 kA, giving solid SCCR headroom for most industrial distribution.

Fieldbus and safety architecture

Slot A accepts interchangeable communication modules: Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen (RJ45, SUB-D 9, or screw terminals). A second slot A/B handles digital/analog I/O or relay expansion. The integrated Modbus serial runs at 4.8–38.4 kbit/s; the Ethernet port does 10/100 Mbit/s with auto-negotiation. Safe Torque Off is rated SIL 3, and the drive also monitors motor phase, thermal, overcurrent, ground faults, and DC bus overvoltages.

MPN
ATV6A0C20S6