Schneider Electric C11N44V025B

C11N44V025B ComPacT NSXm MCCB, 25 A, 50 kA, 4P, MicroLogic 4

MPN C11N44V025B
Active

Schneider Electric ComPacT NSXm, 4P, 25 A at 40 °C, 50 kA 415 V AC, MicroLogic 4.1 electronic trip unit, integrated earth-leakage protection, grey (RAL 7016).

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C11N44V025B key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeEarth leakage circuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
IP ratingIP40
Terminal pitch35 mm with spreaders 27 mm without spreaders
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

C11N44V025B additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degreeclass 3
ColorGrey (RAL 7016)
Depth80 mm
Width108 mm
Height144 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Safety categoryN 50 kA 415 V AC
Operating temperature-25...70 °C

Product details

The Schneider Electric C11N44V025B is a ComPacT NSXm 4-pole moulded-case circuit breaker with a 25 A electronic trip unit (MicroLogic 4.1) and a 50 kA interrupting capacity at 415 V AC — that's the short-circuit rating that determines whether it clears a fault without upstream damage in a 415 V distribution board. The MicroLogic 4.1 is an electronic trip unit with integrated earth-leakage protection — adjustable sensitivity from 30 mA to 5 A for class A or class AC residual currents. That means this single device covers both overcurrent and ground-fault protection, saving a separate RCCB or RCBO in the panel. The thermal memory remembers the last 20 minutes of heating before and after tripping, so it won't reclose immediately onto a still-hot load.

The 12-module 9 mm pitch width (108 mm) and 144 mm height fit standard distribution panel cutouts. Connections are front-facing — both line and load — using compression lugs or busbars. The IP40 front face and IK07 impact rating mean it's protected against tool drops and dust ingress inside a closed panel; it's not rated for washdown environments.

MPN