Skip to main content
Schneider Electric C125N35EFM

Schneider Electric C125N35EFM ComPacT NS, 1250 A, 50 kA at 4

MPN C125N35EFM
Active

Schneider Electric ComPacT NS new generation, C125N35EFM, 3P, 1250 A, MicroLogic 5.0 E electronic trip unit, 50 kA Icu at 415 V AC, fixed mount, front connections.

$3,016.55 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C125N35EFM key specifications
ParameterValue
Control typeManually operated
Display typeLCD display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Utilization categoryCategory B
IP ratingIP40
Terminal pitch70 mm
Connection surface topFront
Connection surface bottomFront

All specifications

C125N35EFM additional specifications
ParameterValue
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947
Depth147 mm
Width210 mm
Height327 mm
Electrical life cycles2000 cycles at 690 V In 3000 cycles at 690 V In/2 4000 cycles at 440 V In 5000 cycles at 440 V In/2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric C125N35EFM is a ComPacT NS new generation molded case circuit breaker (MCCB) from the NS630b...1600 range, rated 1250 A at 50 °C with a MicroLogic 5.0 E electronic trip unit. It is a manually operated, 3-pole device built for distribution applications on AC networks at 50/60 Hz. The 5.0 E trip unit provides LSI protection — long-time overload, short-time short-circuit, and instantaneous short-circuit — plus integrated energy metering via the LCD display.

The 1250 A frame and trip rating at 50 °C sets the continuous current capacity; above 50 °C the breaker must be derated per IEC 60947-2. For selectivity with downstream breakers, the short-time delay (S protection) on the MicroLogic 5.0 E allows coordination up to the Icw rating. The electronic trip unit includes a 20-minute thermal memory, which prevents immediate reclose after a trip on overload by simulating the cooling curve of the protected conductor. Power losses are 44 W at rated current — relevant for enclosure thermal management.

Fixed mounting on a backplate, with front connections on both line and load sides. Connection pitch is 70 mm. The breaker measures 327 mm high, 210 mm wide, and 147 mm deep. IP40 enclosure protection (finger-safe) and IK07 impact resistance.

MPN