Skip to main content
Schneider Electric C125N45EFM

C125N45EFM ComPacT NS 1250A 4P MCCB, MicroLogic 5.0 E, 85 kA

MPN C125N45EFM
Active

Schneider Electric ComPacT NS new generation, C125N45EFM, 4-pole MCCB, 1250 A at 50 °C, MicroLogic 5.0 E electronic trip unit, 85 kA Icu at 220/240 V AC, fixed mount, front connection.

$3,381.39 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C125N45EFM key specifications
ParameterValue
Control typeManually operated
Display typeLCD display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P
Utilization categoryCategory B
IP ratingIP40
Terminal pitch70 mm
Connection surface topFront

All specifications

C125N45EFM additional specifications
ParameterValue
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947
Depth147 mm
Width280 mm
Height327 mm
Electrical life cycles2000 cycles at 690 V In 3000 cycles at 690 V In/2 4000 cycles at 440 V In 5000 cycles at 440 V In/2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The C125N45EFM is a Schneider Electric ComPacT NS new generation 4-pole moulded-case circuit breaker with a MicroLogic 5.0 E electronic trip unit, rated 1250 A at 50 °C. The MicroLogic 5.0 E provides L (long-time overload), S (short-time short-circuit), and I (instantaneous) protection curves, plus an integrated energy meter for distribution monitoring. The 85 kA Icu at 220/240 V AC and 50 kA Icu at 415 V AC (per IEC 60947-2) define the maximum fault current the breaker can safely interrupt without damage — critical for verifying SCCR coordination in the panel. With IP40 protection and IK07 impact rating, it suits indoor switchboard mounting where dust and light mechanical contact are expected, but not washdown environments.

MPN
C125N45EFM