Schneider Electric C4037A400

C4037A400 MicroLogic 7.3 E AL Trip Unit, 400 A, ComPacT NSX

MPN C4037A400
Active

Schneider Electric ComPacT NSX400...630, MicroLogic 7.3 E AL electronic trip unit, 400 A, 3P, LSI with integrated earth-leakage Class A, LCD display, EN/IEC 60947-2.

$22.63 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C4037A400 specifications
ParameterValue
Display typeLCD display
Trip unit typeElectronic
Main product or component typeTrip unit
Voltage440 V AC 50/60 Hz
IP ratingIP40
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The C4037A400 is a MicroLogic 7.3 E AL electronic trip unit from the ComPacT NSX400...630 range, rated 400 A at 40 °C for distribution applications. It packs LSI protection (long-time, short-time, instantaneous) with integrated earth-leakage protection Class A, all in a 3-pole (3D protected poles) package that fits fixed-mount ComPacT NSX breakers. The LCD display gives you local readout of metering, alarms, and event logs — no separate power meter needed on the door.

If your panel runs hotter — say 50 °C inside the enclosure — you'll need to derate per the ComPacT curves, or step up to the next frame size. The Ir long-time pick-up is adjustable from 160 to 400 A, so you can dial in the exact cable or busbar rating without changing hardware. Short-time (Isd) and instantaneous (Ii) pick-ups are also adjustable: Isd from 1.5 to 10 x Ir, Ii from 1.5 to 12 x In. That range covers motor start inrush, transformer magnetizing, and selective coordination with downstream breakers. The short-time delay (tsd) can be set from 0 to 0.4 s with I²t on or off — use I²t on for cable protection, off for generator or busway coordination where you need a flat time band. The IΔn rotary switch lets you disable it (OFF position) if the downstream circuit already has its own RCD, but having it built in saves a separate toroid and relay in the panel. If you re-close quickly on a still-hot circuit, the trip curve shifts to account for the residual heat — no nuisance re-trip on a warm restart, and no waiting for the conductor to cool before re-energizing.

This trip unit mounts into ComPacT NSX400, NSX630, and NSX400...630 fixed-mount circuit breakers. The 3-pole (3D protected) form factor matches the standard NSX frame; the LCD display and pushbuttons are accessible through the breaker's front cover once installed. IP40 per IEC 60529 keeps out tools and wires larger than 1 mm — fine for a clean indoor panel, but if the breaker lives in a washdown area or outdoors, you'll need the IP54 or IP55 shrouded version of the NSX frame. The 50/60 Hz network frequency and 440 V AC rated voltage suit standard low-voltage distribution in North America (480Y/277 V) and Europe (400/230 V) alike.