Schneider Electric C60H1P63AD

Schneider C60H1P63AD MCB, 63A D Curve, 1P, Multi9

MPN C60H1P63AD
Obsolete

Schneider Electric Multi9 C60H, C60H1P63AD, miniature circuit breaker, 63 A, D curve, 1 pole, 15 kA Icu at 230-240 V AC, 73 mm depth.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C60H1P63AD specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage12...440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Depth73 mm
Width18 mm
Height81 mm
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric C60H1P63AD is a C60H-series miniature circuit breaker from the Multi9 range, rated 63 A at 40 °C with a D tripping curve (10...14 x In magnetic limit). It protects a single pole and is built for distribution panels on 35 mm symmetrical DIN rail, occupying 2 x 9 mm pitches (18 mm wide). The thermal-magnetic trip unit handles both overload and short-circuit faults, with a breaking capacity of 15 kA Icu at 230...240 V AC per IEC 60947-2 and 10 kA Icn at 230/400 V AC per EN 60898.

The 15 kA Icu at 230...240 V AC means this breaker can safely interrupt fault currents up to that level without welding or exploding — critical for coordinating with upstream devices in a distribution board. At 400...415 V AC the Icu drops to 4 kA, so verify the prospective short-circuit current at the installation point if feeding a 400 V line. The Ics (service breaking capacity) is 7.5 kA at 230...240 V AC, meaning after clearing a fault at that level the breaker remains functional enough to be reclosed.

D-curve application

At 63 A, the magnetic trip fires between 630 A and 882 A, so it will not nuisance-trip on a motor starting surge that lasts a few cycles. For resistive or general-purpose distribution loads, a C-curve breaker would trip faster on moderate overloads; the D curve trades some sensitivity for inrush immunity.

Panel integration

Snaps onto 35 mm symmetrical DIN rail. The tunnel terminals accept up to 25 mm² flexible or 35 mm² rigid cable, with a tightening torque of 3.5 N.m on both line and load sides. The toggle provides local ON/OFF indication and a contact position indicator confirms the state of the main contacts.

Rated for operation from -25 °C to 60 °C and storage from -40 °C to 70 °C. Tropicalisation per IEC 60068-1 (2 levels) means it withstands 95 % relative humidity at 55 °C without condensation damage — suitable for outdoor cabinets in humid climates. The 6 kV rated impulse withstand voltage (Uimp) per IEC 60947-2 ensures the breaker survives transient surges common in industrial networks.

MPN
C60H1P63AD